Product characteristics | |||
Number of inputs and outputs | Number of digital outputs: 2 | ||
Measuring range | 0...100 bar | 0...1450 psi | 0...10 MPa |
Process connection | threaded connection G 1/4 Internal thread | ||
Application | |||
System | gold-plated contacts | ||
Measuring element | ceramic-capacitive pressure measuring cell | ||
Application | for industrial applications | ||
Media | Liquids | ||
Conditionally suitable for | use in gases at pressures > 25 bar only on request | ||
Medium temperature [°C] | -25...80 | ||
Min. bursting pressure | 650 bar | 9400 psi | 65 MPa |
Pressure rating | 300 bar | 4350 psi | 30 MPa |
Vacuum resistance [mbar] | -1000 | ||
Type of pressure | relative pressure | ||
Electrical data | |||
Operating voltage [V] | 18...30 DC; (to SELV/PELV) | ||
Current consumption [mA] | < 35 | ||
Min. insulation resistance [MΩ] | 100; (500 V DC) | ||
Protection class | III | ||
Reverse polarity protection | yes | ||
Power-on delay time [s] | < 0.3 | ||
Integrated watchdog | yes | ||
Inputs / outputs | |||
Number of inputs and outputs | Number of digital outputs: 2 | ||
Outputs | |||
Total number of outputs | 2 | ||
Output signal | switching signal; IO-Link; (configurable) | ||
Electrical design | PNP/NPN | ||
Number of digital outputs | 2 | ||
Output function | normally open / closed; (configurable) | ||
Max. voltage drop switching output DC [V] | 2.5 | ||
Permanent current rating of switching output DC [mA] | 150; (200 (...60 °C) 250 (...40 °C)) | ||
Switching frequency DC [Hz] | < 170 | ||
Short-circuit protection | yes | ||
Type of short-circuit protection | yes (non-latching) | ||
Overload protection | yes | ||
Measuring/setting range | |||
Measuring range | 0...100 bar | 0...1450 psi | 0...10 MPa |
Factory setting / CMPT = 2 | |||
Set point SP | 1...100 bar | 10...1450 psi | 0.1...10 MPa |
Reset point rP | 0.5...99.5 bar | 5...1445 psi | 0.05...9.95 MPa |
Min. difference between SP and rP | 0.5 bar | 10 psi | 0.05 MPa |
In steps of | 0.5 bar | 5 psi | 0.05 MPa |
Status_B High Resolution / CMPT = 3 | |||
Set point SP | 0.8...100 bar | 12...1450 psi | 0.08...10 MPa |
Reset point rP | 0.3...99.5 bar | 5...1443 psi | 0.03...9.95 MPa |
Min. difference between SP and rP | 0.5 bar | 8 psi | 0.05 MPa |
In steps of | 0.1 bar | 1 psi | 0.01 MPa |
Accuracy / deviations | |||
Switch point accuracy [% of the span] | < ± 0,5 | ||
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) | ||
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | ||
Hysteresis deviation [% of the span] | < ± 0,25 | ||
Long-term stability [% of the span] | < ± 0,05; (per 6 months) | ||
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (-0...80 °C) | ||
Temperature coefficient span [% of the span / 10 K] | < ± 0,2; (-0...80 °C) | ||
Reaction times | |||
Response time [ms] | < 3 | ||
Delay time programmable dS, dr [s] | 0...50 | ||
Software / programming | |||
Parameter setting options | hysteresis / window; normally open / closed; switching logic; switch-on/switch-off delay; Damping; Display unit | ||
Interfaces | |||
Communication interface | IO-Link | ||
Transmission type | COM2 (38,4 kBaud) | ||
IO-Link revision | 1.1 | ||
SDCI standard | IEC 61131-9 | ||
SIO mode | yes | ||
Required master port class | A; (when pin 2 not connected: B) | ||
Process data analog | 1 | ||
Process data binary | 2 | ||
Supported DeviceIDs | Type of operation | DeviceID | |
Factory setting / CMPT = 2 | 401 | ||
PN7002 | 309 | ||
Status_B High Resolution / CMPT = 3 | 599 | ||
Note | For further information please see the IODD PDF file at "Downloads" |