Product Description
Material number:
X20AI1744-3
Description:
1 full-bridge strain gauge input
Data output rate configurable from 0.1 Hz to 7.5 kHz
Special operating modes (synchronous mode and multiple sampling)
Configurable filter level
This module works with both 4-wire and 6-wire strain gauge load cells. The concept applied by the module requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero point offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature.
Product Information
Short description
I/O module | 1 full-bridge strain gauge input |
General information
B&R ID code | 0xA4EF |
Status indicators | Channel status, operating state, module status |
Diagnostics |
|
Module run/error | Yes, using LED status indicator and software |
Open circuit | Yes, using LED status indicator and software |
Input | Yes, using LED status indicator and software |
Power consumption |
|
Bus | 0.01 W |
Internal I/O | 0.5 W |
Additional power dissipation caused by actuators (resistive) [W] | Max. +0.36 |
Certifications |
|
CE | Yes |
UKCA | Yes |
ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc |
UL | cULus E115267 |
HazLoc | cCSAus 244665 |
KC | Yes |
Full-bridge strain gauge
Strain gauge factor | 2 to 256 mV/V, configurable using software |
Connection | 4- or 6-wire connections |
Input type | Differential, used to evaluate a full-bridge strain gauge |
Digital converter resolution | 24-bit |
Conversion time | Depends on the configured data output rate |
Data output rate | 0.1 - 7500 samples per second, configurable using software (fDATA) |
Input filter |
|
Cutoff frequency | 5 Hz |
Order | 3 |
Slope | 60 dB |
ADC filter characteristics | Sigma-delta, see section "Filter characteristics of the sigma-delta A/D converter" |
Operating range / Measurement sensor | 85 to 5000 Ω |
Influence of cable length | See section "Calculation example". |
Input protection | RC protection |
Common-mode range | 0 to 3 VDC |
Insulation voltage between input and bus | 500 Veff |
Conversion procedure | Sigma-delta |
Output of digital value |
|
Broken bridge supply line | Value approaching 0 |
Broken sensor line | Value approaching ±end value (status bit "Line monitoring" is set in register "Module status") |
Valid range of values | 0xFF800001 to 0x007FFFFF (-8,388,607 to 8,388,607) |
Strain gauge supply |
|
Voltage | 5.5 VDC / Max. 65 mA |
Short-circuit and overload-proof | Yes |
Voltage drop for short-circuit protection | Max. 0.2 VDC at 65 mA and 25°C |
Quantization |
|
LSB value (16-bit) |
|
2 mV/V | 336 nV |
4 mV/V | 671 nV |
8 mV/V | 1.343 µV |
16 mV/V | 2.686 µV |
32 mV/V | 5.371 μV |
64 mV/V | 10.74 μV |
128 mV/V | 21.48 μV |
256 mV/V | 42.97 μV |
LSB value (24-bit) |
|
2 mV/V | 1.31 nV |
4 mV/V | 2.62 nV |
8 mV/V | 5.25 nV |
16 mV/V | 10.49 nV |
32 mV/V | 20.98 nV |
64 mV/V | 41.96 nV |
128 mV/V | 83.92 nV |
256 mV/V | 167.85 nV |
Temperature coefficient |
|
Rev. ≥E0 | 10 ppm/°C |
Rev. <E0 | 30 ppm/°C |
Max. gain drift | 12 ppm/°C |
Max. offset drift | 2 ppm/°C |
Nonlinearity | <10 ppm |
Electrical properties
Electrical isolation | Bus isolated from analog input and strain gauge supply voltage |
Operating conditions
Mounting orientation |
|
Horizontal | Yes |
Vertical | Yes |
Installation elevation above sea level |
|
0 to 2000 m | No limitation |
>2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
Degree of protection per EN 60529 | IP20 |
Ambient conditions
Temperature |
|
Operation |
|
Horizontal mounting orientation | -25 to 60°C |
Vertical mounting orientation | -25 to 50°C |
Derating | See section "Hardware configuration" |
Storage | -40 to 85°C |
Transport | -40 to 85°C |
Relative humidity |
|
Operation | 5 to 95%, non-condensing |
Storage | 5 to 95%, non-condensing |
Transport | 5 to 95%, non-condensing |
Mechanical properties
Note | Order 1x terminal block X20TB12 separately. |
Pitch | 12.5+0.2mm |
Product Photo
More Products
Mandatory Accessories
Bus modules
Terminal blocks
X20PS9600 | X20SO6300 | X20DC4395 |
X20CP0483 | X20SLX210 | X20BT9100 |
X20CP1483 | X20DI4371 | X20DI9371 |
x20cp1586 | X20BM05 | X20AT6402 |
X20CP1583 | X20BC0083 | X20AI4622 |
X20CP3584 | X20BC8083 | x20at4222 |
X20CP3583 | X20BB80 | x20bt9400 |
X20CP1585 | X20BM11 | X20AT2222 |
X20CP1584 | X20TB12 | X20AO4622 |
X20CP1684 | X20IF1072 | X20DO9322 |
X20CP1382 | X20DO6322 | X20IF1030 |
X20AI1744 | X20DC2395 | X20IF1082-2 |
X20DI6371 | X20BM15 | X20IF371 |
X20DOF322 | X20DO4332 | X20CM4810 |
X20DS4389 | X20DO4322 | X20AI83211 |
X20PS2100 | X20MM2436 | X20DOF322 |
X20PS9400 | X20DO8332 | X20PS3330 |
X20CS1030 | X20DC11A6 | X20BM01 |
X20CS1020 | X20CM8281 | X20SI9100 |
X20ATC402 | X20BR9300 | X20SI4100 |
Cooperative Brand
(DCS)
ABB / TRICONEX / FOXBORO/ I/A / HONEYWELL / TDC2000/3000 / YOKOGAWA / BENTLY NEVADA
(PLC)
B&R / ALLEN BRADLEY / BECKHOFF / HONEYWELL / OMRON / SIEMENS
(SENSOR)
IFM / SICK/ P+F/ WENGLOR / BAUMER / LEUZE / HOLLY/ SYSHOKUYO / EUCHNER
(CONNECTOR)
HARTING / PHOENIX CONTACT/ WEIDMUELLER
(VALVE)
SMC / FESTO / +GF+.......
(INSTRUMENT)
+GF+ /E+H / HITACHI / ROSEMOUNT
Why Choose Us
Xiamen ZhiCheng Automation Technology Co., Ltd it is a leading global supplier of control system components. We specialize in control systems and drives. With many years of experience in the industrial sector, we consistently deliver the highest quality of spare parts. We have tens of thousands of spare partsand spare parts warehouse . Products and services to serve for installing of users control system,Distributed control systems, programmable controllers, panel controller and drive!
We major in DCS system,Sensor,PLC,Connector,Valve, and Instrument,MAGNETRON,RO Membrane. With many years of experience in the industrial sector, we consistently deliver the highest quality of spare parts.which make sure that all this jobs are perfectly. If you have any further questions, please don't hesitate to contact us.
How To Contact Me