Attribute |
Value |
Unit |
Description |
---|---|---|---|
Model Number |
80VD100PD.C022-01 |
- |
Product identifier |
Type |
ACOPOSmicro Inverter Module |
- |
Dual-axis servo drive for motion control systems |
Control Capacity |
2 Servo Motors |
- |
Simultaneous control of two independent axes |
Power Supply |
24-64 VDC ±25% |
VDC |
Wide input voltage range with transient tolerance |
Continuous Current |
8 |
A |
Rated RMS current per motor |
Peak Current |
15 |
A |
Short-term overload capability |
Switching Frequency |
5/10/20/40 |
kHz |
Adjustable PWM frequency for motor control |
Interface |
X2X POWERLINK (RJ45) |
- |
Real-time Ethernet-based communication protocol |
Feedback Type |
2x Resolver |
- |
Supports analog resolver feedback for position/speed tracking |
Inputs |
2 Digital (24 VDC Sink) |
- |
Configurable as trigger inputs for external events |
Outputs |
1 Digital (24 VDC, 1 A) |
- |
Status indication or control signal |
Safety Features |
Motor Holding Brake, Overload/Short-circuit Protection |
- |
Built-in safety mechanisms for fail-safe operation |
Protection Class |
IP20 |
- |
Basic dust protection (requires enclosure for higher ratings) |
Certifications |
CE, UL (E225616), Functional Safety Compliance |
- |
Meets international safety standards for industrial applications |
Cooling Method |
Passive (Screw Mounted) |
- |
Requires heat spreader for thermal management |
Dimensions (W×H×D) |
65×140×125 |
mm |
Compact form factor for space-constrained installations |
Weight |
1.4 |
kg |
Lightweight design for easy integration |
Operating Temperature |
0–45 (with derating up to 55) |
°C |
Temperature range with derating requirements |
Storage Temperature |
-25–55 |
°C |
Non-operational temperature tolerance |
Relative Humidity |
5–85% (Non-condensing) |
- |
Moisture resistance for industrial environments |
Bus Capacitance |
940 |
µF |
DC link capacitance for stable power delivery |
Braking Support |
External Brake Resistor |
- |
Optional connection for regenerative braking |
Terminal Requirements |
Sold Separately |
- |
Requires dedicated terminal blocks for power/signal connections |