Product characteristics | ||||||||||
Number of inputs and outputs | Number of analog outputs: 1 | |||||||||
Process connection | G 1/2 external thread | |||||||||
Application | ||||||||||
System | gold-plated contacts | |||||||||
Media | Conductive liquids | |||||||||
Note on media | water | |||||||||
milk | ||||||||||
CIP liquids | ||||||||||
Cannot be used for | See the operating instructions, chapter "Function and features". | |||||||||
Medium temperature [°C] | -25...100; (< 1 h: 150) | |||||||||
Pressure rating [bar] | 16 | |||||||||
Vacuum resistance | [mbar] | -1000 | ||||||||
Electrical data | ||||||||||
Operating voltage | [V] | 18...30 DC | ||||||||
Current consumption [mA] | < 60 | |||||||||
Protection class | III | |||||||||
Reverse polarity protection | yes | |||||||||
Power-on delay time | [s] | 2 | ||||||||
Inputs / outputs | ||||||||||
Number of inputs and outputs | Number of analog outputs: 1 | |||||||||
Outputs | ||||||||||
Total number of outputs | 1 | |||||||||
Output signal | analog signal; | IO-Link | ||||||||
Output function | analog output; scalable; selectable conductivity / temperature | |||||||||
Number of | analog outputs | 1 | ||||||||
Analog current output | [mA] | 4...20 | ||||||||
Max. load | [Ω] | 500 | ||||||||
ifmefector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — LDL100-01 — 13.09.2019 — | ||||||||||
LDL100 | ||||||||||
Conductive conductivity sensor | ||||||||||
COND CONDUCTIVITY HYG G1/2 | ||||||||||
Measuring/setting range | ||||||||||
Measuring range | [µS/cm] | 100...15000 | ||||||||
Temperature measurement | ||||||||||
Measuring range | [°C] | -25...150 | ||||||||
Accuracy / deviations | ||||||||||
Accuracy (in the measuring | 10 % MW ± 25 µS/cm | |||||||||
range) | ||||||||||
Conductivity measurement | ||||||||||
Resolution | [µS/cm] | 1 | ||||||||
Drift | [%/K] | 0,2 %/K MW ± 25 µS/cm | ||||||||
Repeatability | 5 % MW ± 25 µS/cm | |||||||||
Long-term stability | 1 % MW ± 25 µS/cm | |||||||||
Temperature measurement | ||||||||||
Accuracy | [K] | 20...50 °C: < ± 0,5 K; -25...150 °C: < ± 1,5 K | ||||||||
Repeatability | [K] | 2 | ||||||||
Resolution | [K] | 0.1 | ||||||||
Reaction times Conductivity measurement | ||||||||||
Response time [s] | < 2; (T09; Damping = 0) | |||||||||
Temperature measurement | ||||||||||
Response time [s] | < 9; (T09) | |||||||||
Interfaces | ||||||||||
Communication interface | IO-Link | |||||||||
Transmission type | COM2 (38,4 kBaud) | |||||||||
IO-Link revision | 1.1 | |||||||||
SDCI standard | IEC 61131-9 | |||||||||
IO-Link device ID | 0x000399 / 921 | |||||||||
Profiles | Measuring Sensor, Identification and Diagnosis | |||||||||
SIO mode | no | |||||||||
Required master port class | A | |||||||||
Process data analogue | 1 | |||||||||
Min. process cycle time [ms] | 5.6 | |||||||||
Operating conditions | ||||||||||
Ambient temperature [°C] | -40...60 | |||||||||
Storage temperature [°C] -40...85 Protection IP 68; IP 69K; (IP 68: 7 days / 3 m water depth / 0.3 bar) | ||||||||||
Tests / approvals | ||||||||||
EMC | DIN EN 61000-6-2 | |||||||||
DIN EN 61000-6-3 | ||||||||||
Shock resistance | DIN EN 60068-2-27 | 50 g (11 ms) | ||||||||
Vibration resistance | DIN EN 60068-2-6 | 20 g (10...2000 Hz) | ||||||||
MTTF [years] | 172 | |||||||||
ifmefector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — LDL100-01 — 13.09.2019 — | ||||||||||
LDL100 | ||||||||||
Conductive conductivity sensor | ||||||||||
COND CONDUCTIVITY HYG G1/2 | ||||||||||
Mechanical data | ||||||||||
Weight [g] | 270.5 | |||||||||
Material | stainless steel (1.4404 / 316L); PEEK; PEI; FKM | |||||||||
Materials (wetted parts) PEEK; stainless steel (1.4404 / 316L) Process connection G 1/2 external thread | ||||||||||
Remarks | ||||||||||
Remarks | MW = Measured value | |||||||||
Pack quantity | 1 pcs. | |||||||||
Electrical connection |