Attribute |
Details |
---|---|
General Information |
|
Product Type |
Inductive Proximity Sensor |
Model |
NBB20-U1-A0-M |
Manufacturer |
Pepperl+Fuchs |
Sensing Characteristics |
|
Rated Operating Distance |
20 mm (flush mounting) |
Assured Operating Distance |
0–16.2 mm (guaranteed reliable detection range) |
Metal Reduction Factors |
Aluminum (0.33), Copper (0.31), Stainless Steel 304 (0.74) |
Switching Function |
Normally Open (NO) |
Electrical Parameters |
|
Supply Voltage |
10–30 V DC |
Output Type |
3-wire DC NPN (sinking) |
Nominal Operating Current |
0–200 mA |
Off-State Current |
≤ 0.5 mA (typical 0.1 μA at 25°C) |
No-Load Supply Current |
≤ 20 mA |
Voltage Drop |
≤ 2 V |
Switching Frequency |
0–440 Hz (high-speed operation) |
Hysteresis |
Approx. 5% (minimizes signal oscillations) |
Electrical Protection |
Reverse polarity protection; pulsing short-circuit protection; overload protection |
Indicators |
|
LEDs |
4 x 360° visible LEDs: Green (power status), Yellow (switching state) |
Mechanical Design |
|
Housing Material |
PA (polyamide) with metal base and epoxy powder coating (corrosion/impact resistance) |
Sensing Face Material |
Polyamide (PA) |
Dimensions |
118 mm (L) × 40 mm (W) × 40 mm (H) |
Weight |
225 g |
Mounting |
Flush-mountable with bidirectional/rotatable sensor head |
Connection |
Screw terminals (supports 0.5–2.5 mm² conductors, 1.2 Nm tightening torque) |
Environmental Ratings |
|
IP Rating |
IP67 (dust-tight and protected against temporary water immersion) |
Operating Temperature Range |
-25°C to +85°C (ambient); -40°C to +85°C (storage) |
Certifications & Approvals |
|
Standards |
EN IEC 60947-5-2 (industrial switchgear safety), RoHS compliant |
Approvals |
cULus listed (USA/Canada), CCC exempt (≤36 V DC) |
Functional Safety |
|
MTTFd (Mean Time To Failure) |
1,289 years (estimated reliability for non-safety-integrated systems) |
Mission Time (Tm) |
20 years |
Diagnostic Coverage (DC) |
0% |
Applications |
Industrial automation, conveyor systems, robotic positioning, automotive manufacturing, and harsh environments requiring dust/water resistance (e.g., metalworking, logistics, food processing) |