Solenoid Electromagnetic Induction Coil 400425205, 400425-117
Ordering Code:
400325-105, 400325-205, 400425-105, 400425-205 , 400525-105, 400525-205
400325-118 , 400325-218, 400425-118, 400425-218 , 400525-118, 400525-218
400325-117, 400325-217, 400425-117, 400425-217 , 400525-117, 400525-217
| DC24V= | DC48V= | AC24V= | AC48V= | AC115V= | AC230V= |
CM-6 CM-6 CM6FT CM6FB | 234511-006 238511-106 400325-142 400325-242 | 400325-144 400325-244 | 400325-101 400325-201 | 400325-105 400325-205 | 400325-118 400325-218 | 238211-057 238211-157 400325-117 400325-217 |
CM-XX CM-XX CMXX-FT CMXX-FB CMXX-FF CM12-FT CM12-FB | 238911-006 238911-106 400425-142 - 400425-342 400625-142 400625-242 | 400425-144 - 400425-344 400625-144 400625-244 | 400425-101 400425-201 - 400525-101 400525-201 | 400425-105 400425-205 - 400525-105 400525-205 | 400425-118 400425-218 - 400525-118 400525-218 | 238611-057 238611-157 400425-117 400425-217 - 400525-117 400525-217 |
Pulse valve is mainly used in environmental dust industries, such as electromagnetic or pneumatic control by the pilot valve can open and close the high-pressure gas source to generate pulse valve diaphragm valve in an instant , but also commonly known as electromagnetic pulse were pulsed valve or gas control valve .
what's it used for?
Electromagnetic pulse valve ( also called diaphragm valve ) is a pulse jet bag filter cleaning system air "switch", Control pulse controller output signal control, bag- by-row ( room ) injection cleaning , so dust resistance remain within the set range, in order to ensure the processing power and dust collection efficiency .
Z type pulse valve for the right angle , the angle between the import and export of 90 °, suitable for mounting the air bag and the link between the injection tube , air flow, providing cleaning gas pulses to meet the requirements .
Y type is submerged pulse valve ( also known as embedded valve ) , it is mounted directly on the air bag has better flow characteristics . Pressure loss decreased for the lower air pressure in the workplace .
How it works?
Before the diaphragm into the electromagnetic pulse valve , after two chambers , when connected to compressed air , compressed air through the orifice into the gas chamber , when the diaphragm chamber pressure will close the valve outlet , electromagnetic pulse valve is in the " off" state.
Electrical pulse controller of the pulse valve armature moves , the bleed hole to open the valve chamber , the gas chamber after rapid loss of pressure . After the diaphragm moves , blowing compressed air through the valve outlet . The pulse is "on" state.
Pulse jet control device signals disappear , electromagnetic pulse valve armature reset , after the chamber put stomatal closure , after the chamber pressure rises close to the diaphragm valve outlet , electromagnetic pulse valve is in the "off " state.
Pressure range(MPA) | 0.2~0.8 |
Ambient temperature(℃) | -5~55 |
Use Media | Cleaning Air |
Relative Humidity | ﹤85% |
Voltage | DC24V AC220V |
