Description:
Very high performance diaphragm valve with flanged inlet port and slide seal outlet port for easy valve installation and removal.
Available with integral pilot or as remotely piloted valve.Outlet at 90°.
Operation
Recommended,
On time range:50-500ms
Recommeded time
between pulses:1 minute or greater
Installation:
1.Prepare inlet flange and blowtube pipes to suit valve specification.
Avoid installing valves underneath the tank.
2.Ensure tank and Pipes are free from dirt,rust or other particulate.
3.Ensure supply air is clean and dry.
4.Mount valves to inlet flange and blowtube to valves with all seals in place.
Tighten flange bolts to 10Nm(7.4ft-ibs) Ensure blowtube is oushed all the way into the valve outlet.
5.Tanks and pipes must be independently restrained from valve.
6.Make electrical connections to solenoid or connect RCA pilot port to pilot valve.(RCA valve only).
7.Apply moderate pressure to system and check for installation leaks.
8.Fully pressurise system.
9.Test fire and listen for proper actuation and crisp pulse noise.
Product show: