Product Description:
SIRIUS soft starter S0 32 A, 15 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC Screw terminals Thermistor motor protection.
General technical data | |
product brand name | SIRIUS |
product feature | |
● integrated bypass contact system | Yes |
● thyristors | Yes |
product function | |
● intrinsic device protection | Yes |
● motor overload protection | Yes |
● evaluation of thermistor motor protection | Yes |
● external reset | Yes |
● adjustable current limitation | Yes |
● inside-delta circuit | No |
product component motor brake output | No |
insulation voltage rated value | V 600 |
degree of pollution | 3, acc. to IEC 60947-4-2 |
reference code according to EN 61346-2 | Q |
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750 | G |
Power Electronics | |
product designation | Soft starter |
operational current | |
● at 40 °C rated value | A 32 |
● at 50 °C rated value | A 29 |
● at 60 °C rated value | A 26 |
yielded mechanical performance for 3-phase motors | |
● at 230 V | |
— at standard circuit at 40 °C rated value | kW 7.5 |
● at 400 V | |
— at standard circuit at 40 °C rated value | kW 15 |
yielded mechanical performance [hp] for 3-phase AC | hp 7.5 |
motor at 200/208 V at standard circuit at 50 °C rated | |
value | |
operating frequency rated value | Hz 50 ... 60 |
relative negative tolerance of the operating frequency | -10% |
relative positive tolerance of the operating frequency | 10% |
operating voltage at standard circuit rated value | V 200 ... 480 |
relative negative tolerance of the operating voltage at | -15% |
standard circuit | |
relative positive tolerance of the operating voltage at | 10% |
standard circuit | |
10% | |
minimum load [%] % 20 | 20% |
adjustable motor current for motor overload | A 17 |
protection minimum rated value | |
continuous operating current [% of Ie] at 40 °C | 115% |
power loss [W] at operational current at 40 °C during | W 13 |
operation typical | |
Control circuit/ Control | |
type of voltage of the control supply voltage | AC/DC |
control supply voltage frequency 1 rated value | Hz 50 |
control supply voltage frequency 2 rated value | Hz 60 |
relative negative tolerance of the control supply | -10% |
voltage frequency | |
relative positive tolerance of the control supply | 10% |
voltage frequency | |
control supply voltage 1 at AC | |
● at 50 Hz rated value | V 24 |
● at 60 Hz rated value | V 24 |
relative negative tolerance of the control supply | -15% |
voltage at AC at 50 Hz | |
relative positive tolerance of the control supply | 10% |
voltage at AC at 50 Hz | |
relative negative tolerance of the control supply | -15% |
voltage at AC at 60 Hz | |
relative positive tolerance of the control supply | 10% |
voltage at AC at 60 Hz | |
control supply voltage 1 at DC rated value V 24 | -20% |
relative negative tolerance of the control supply | |
voltage at DC | |
relative positive tolerance of the control supply | 20% |
voltage at DC | |
display version for fault signal | red |
Mechanical data | |
size of engine control device | S0 |
width | mm 45 |
height | mm 125 |
depth | mm 155 |
fastening method | screw and snap-on mounting |
mounting position | With additional fan: With vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back Without additional fan: With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° t |
required spacing with side-by-side mounting | |
● upwards | mm 60 |
● at the side | mm 15 |
● downwards | mm 40 |
wire length maximum | m 300 |
number of poles for main current circuit | 3 |
Connections/ Terminals | |
type of electrical connection | |
● for main current circuit | screw-type terminals |
● for auxiliary and control circuit | screw-type terminals |
number of NC contacts for auxiliary contacts | 0 |
number of NO contacts for auxiliary contacts | 2 |
number of CO contacts for auxiliary contacts | 1 |
type of connectable conductor cross-sections for | |
main contacts for box terminal using the front | |
clamping point | |
● solid | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), max. 1x 10 mm² |
● finely stranded with core end processing | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²) |
type of connectable conductor cross-sections at AWG | |
cables for main contacts for box terminal | |
● using the front clamping point | 1x 8, 2x (16 ... 10) |
type of connectable conductor cross-sections for | |
auxiliary contacts | |
● solid | 2x (0.5 ... 2.5 mm²) |
● finely stranded with core end processing | 2x (0.5 ... 1.5 mm²) |
type of connectable conductor cross-sections at AWG | |
cables | |
● for auxiliary contacts | 2x (20 ... 14) |
● for auxiliary contacts finely stranded with core end processing | 2x (20 ... 16) |
Ambient conditions | |
installation altitude at height above sea level | m 5 000 |
environmental category | |
● during transport according to IEC 60721 | 2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) |
● during storage according to IEC 60721 | 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 |
● during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
ambient temperature | |
● during operation | °C -25 ... +60 |
● during storage | °C -40 ... +80 |
derating temperature | °C 40 |
protection class IP on the front according to IEC 60529 | IP20 |
touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front |
UL/CSA ratings | |
yielded mechanical performance [hp] for 3-phase AC motor | |
● at 220/230 V | |
— at standard circuit at 50 °C rated value hp 7.5 | hp 7.5 |
● at 460/480 V | |
— at standard circuit at 50 °C rated value | hp 20 |
contact rating of auxiliary contacts according to UL | B300 / R300 |
Dimensional drawings: