Goyen Type CA35T Right Angle 1-1/4'' Diaphragm Pulse Jet Valve
Pulse jet valves common fault handling methods:
The air bag capacity is too small, or the air supply pipe of the air bag is too small, and the air supply after the injection is insufficient, the pulse solenoid valve cannot be closed normally (closed), and the diaphragm oscillates (resonance phenomenon).
Treatment: connect several small air bags into a large-capacity gas storage circuit; place the gas-regulated gas tank as close as possible to the dust collector air bag and add the air-filled gas supply pipe.
The pulse width of the pulse solenoid valve is too long, and the coil is energized for a long time, which causes electromagnetic memory. The push rod in the electromagnetic pilot valve cannot be reset, the diaphragm cannot be closed, the residual pressure in the air bag is too low, and the air supply is insufficient. .
Solution: Replace the pulse solenoid push rod and replace the upper cover of the small diaphragm if necessary.
Technical Data of Goyen Pulse Jet Valve:
Model No | CA15T | CA20T | CA25T | CA35T | CA45T | CA50T | CA62T | CA76T |
Nonimal size | φ15 | φ20 | φ25 | φ35 | φ45 | φ50 | φ62 | φ76 |
Port Size | G1/2'' | G3/4'' | G1'' | G1 1/4'' | G1 1/2'' | G2'' | G2 1/2'' | G3'' |
Working pressure | 0.3-0.8MPa | |||||||
Temp. range | -5℃ - 55℃ | |||||||
Relative humidity | ≤85% | |||||||
Working medium | Compressed clean air | |||||||
Service life | Over 1000000 times | |||||||
Voltage | DC24V, AC24V, AC110V, AC220V |
Main Dimension:
CA RCA Series Pulse Jet Valve For Dust Collector System:
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!