6011 Type Direct Acting Plunger Miniature Solenoid Valve 2 Way G1/8'' AC220V
The Type 6011 Direct Acting 2/2 Way Miniature Solenoid Valve is plunger direct operated and used for shut-off, dosing, filling, ventilating and for technical vacuum. A compact, small format valve with diameter of up to DN 2.4mm. The valve benefits from having the stopper and plunger guiding tube welded together, helping to enhance pressure resistance and leak-tightness.
Key features:
Body matereial: Brass.
Seal material: FKM.
Thread port size: G1/8''.
Orifice sizes: 1.2mm, 1.6mm, 2.0mm and 2.4mm.
Normal voltages: 24V DC, 24V AC, 110V AC and 230V AC.
Medium temperature: 0°C to +100°C.
Ambient temperature: +55°C.
Pressure range: 0-12 Bar (depending on configuration).
Main Dimension of 6011 Type Plunger Miniature Solenoid Valve:
Technical parameters of Type 6011 Miniature Plunger Solenoid Valve:
Orifice (mm) | Port connection | Kv value water (m³/h) | Pressure range (bar) | Voltage / Frequency (V/Hz) |
1.2 | M5 | 0.045 | 0 - 12 | 24/DC |
0 - 21 | 24/50 | |||
0 - 21 | 110/50 | |||
0 - 21 | 230/50 | |||
1.6 | M5 | 0.06 | 0 - 6 | 24/DC |
0 - 12 | 24/50 | |||
0 - 12 | 110/50 | |||
0 - 12 | 230/50 | |||
G1/8'' | 0.06 | 0 - 6 | 24/DC | |
0 - 12 | 24/50 | |||
0 - 12 | 110/50 | |||
0 - 12 | 230/50 | |||
2.0 | G1/8'' | 0.11 | 0 - 4.5 | 24/DC |
0 - 8 | 24/50 | |||
0 - 8 | 110/50 | |||
0 - 8 | 230/50 | |||
2.4 | G1/8'' | 0.13 | 0 - 3 | 24/DC |
0 - 6 | 24/50 | |||
0 - 6 | 110/50 | |||
0 - 6 | 230/50 |
Main Part & Material of 6011 Direct Acting Plunger Miniature Solenoid Valve:
Show Details of 2/2 Way G1/8'' 6011 Type Miniature Solenoid Valve:
More displays of AC220V 6011 Type NC Plunger Solenoid Valve:
Intended use of 6011 Type Plunger Miniature Solenoid Valve:
Incorrect use of the Model 6011 may pose a hazard to personnel, nearby equipment and the environment.
1. 6011 solenoid valve is designed to block, meter, fill and discharge neutral gaseous and liquid media.
2. In areas where there is a risk of explosion, the device should only be used according to the instructions on the separate Ex-label. When using, please follow the other information provided with the device and the safety instructions in the explosion hazard area.
3. Equipment that does not have a separate explosion-proof type label must not be used in areas where there is a risk of explosion.
4. Use according to the authorization data, operating conditions, and the conditions of use specified in the contract documents and operating instructions.
5. Use the device only in good condition and always ensure proper storage, transportation, installation and operation.
6. Use the device only as intended.
Welcome to your any question and inquiry!