CCTV DC Boxed Switching Power Supply
Key Feature:
Model: PSB1205-4
Input: AC100-240V, 50-60Hz
Output: DC12V, 5A, 4Port Channels
AC Input Plug: US,EU,UK,etc.available
Multiple Protection: Over Current/Voltage/Load (PTC Fuse)
Box Size: 17.3cm*12cm*6.5cm, 1kg/piece
Specification
Item |
12V DC, 5A, 4 Channels Boxed CCTV Power Supply |
||
Model |
PSB1205-4 |
||
Output |
Voltage |
12 V |
|
Current (Rated) |
5 A |
||
Power (Rated) |
60 W |
||
Output Ports |
4 |
||
Ripple/Noise (Max.) |
150mVp-p |
||
Voltage (Adjust Range) |
4.75-5.5 V |
||
Voltage Accuracy |
±2.0% |
||
Line Regulation |
±1.5% |
||
Load Regulation |
±1.5% |
||
Time(Start, Rise, Hold) |
1000ms, 30ms/230VAC, 1000ms,30ms/115VAC(Full-Load) |
||
Input |
Voltage (Range) |
85-264 V AC |
120-370 V DC |
Frequency (Range) |
47-63 Hz |
||
Efficiency (Typ) |
79% |
81% |
|
AC Current |
0.3A/115V AC |
0.25A/230V AC |
|
Surge Current |
Cold boot: 40A/100V AC |
80A/230V AC |
|
Leakage Current (Max) |
<2mA/240V AC |
||
Protection |
Over Load |
Not over 105% rated output power |
|
Mode: Hiccup Mode, Recover after removing the over-load |
|||
Over Voltage |
5.75-6.75V |
13.8-16.2V |
|
Mode: Shut down the output, Zener diode clamp |
|||
Over Temperature |
Protection will be triggered when the temperature of connect point inside the transistor over 140℃ |
||
Mode: Shut down the output, Auto-recover after the temperature return to normal value. |
|||
Environment |
Operate Temperature |
-20 ~ 60 ℃ |
|
Operate Humidity |
20 ~ 90%RH, no condensing |
||
Storage Temperature |
-40% ~ 85 ℃ |
||
Storage Humidity |
95%RH, no condensing |
||
Temperature Factor |
±0.03%/℃(0 ~ 45℃) |
||
Vibration Resistance |
10 ~ 500Hz, 2G10mins/cycle, X,Y,Z axis each 60 minutes |
||
Safety & EMC |
Safety Specification |
UL60950-1, CB(IEC60950-1), CCC GB4943.1:2011 Approved |
|
Electric Strength |
I/P ~ O/P:3KVDC; I/P ~ FG:2KVDC; 0/P ~ FG:0.5KVDC |
||
Insulation Resistance |
I/P ~ O/P , I/P ~ FG , 0/P ~ FG:100M Ohms/500VDC/25℃/70%RH |
||
EMC Radiation |
Conform to EN55022(CISPR22) ClassB,EN61000-3-2,3 |
||
EMC Immunity |
Conform to EN61000-4-2,3,4,5,6,11,EN55024,EN61000-6-1, A level QB SG |
||
MTBF |
≥563.5Khrs MIL-HDBK-217F(25℃) |
||
Note |
1. All specs and parameter, in the absence of special note, are measured base on 230VAC Input, Rate Loading, 25℃, 70%RH environment. |
||
2. Volts D.C. Measuring Method: measure at the end of plug-in terminal under 50% loading condition |
|||
3. Ripple/Noise measuring method: Use a 12" twisted pair and terminal parallel connecting with 0.1uf and 47uf capacitance and measure in 20MHZ bandwidth |
|||
4. Accuracy: Include assigned error, Line regulation, Load regulation |
|||
5. Line Regulation Measurement: Measure range from low voltage to high voltage under rated loading |
|||
6. Load Regulation Measurement: Measure range from 0% to 100% |
|||
7. According to the rule GB4943.1, power supply only applicable in the place where elevation lower than 2000m and non-tropical climate area safely |
|||
8. Power supply shall be deemed to be part of system components, so it has to be applied based on electromagnetic related confirmation. |