Swimming pool water Proportional automatic temperature control system
Equipment features
In order to keep the system running at the set temperature during the daily operation, it is necessary to adjust the flow rate of the heat medium through the hearing equipment to maintain its dynamic balance. Therefore, each heating equipment must be equipped with temperature detection and control devices.
The water temperature sensor installed on the circulating water pipe converts the detected real-time pool water temperature signal into the analog signal, and then enters the temperature controller and compare with the set temperature. Then the controller outputs an action signal to the heat medium temperature electric regulating valve, and automatically increases or decrease the valve opening angle according to actual needs, thereby achieving the purpose of adjusting the heat flow and constant temperature.
Proportional automatic temperature control system | |||
Component | Multi-function controller | Water temperature sensor | Electric temperature regulating valve (valve & actuator) |
Temperature range | -35~150℃ | 0~250℃ | -15~200℃ |
Precision | 0.5℃ | 0.1℃ | / |
Output and input signal | 4-20mA | / | 4-20mA |
Power supply | 24V | / | 220V |
Installation method | Counter installation | Immersion installation | Pipe installation |
System attachment | Electric cabinet, transformer, installation attachment |