KE7302 Portable Three Phase Reference Standard Meter
Accuracy : 0.2, Test method: clamp CT and terminal input. It's light and small, which is convenient for on-site test, and can be used to test the error of three phase energy meters and field electrical parameters of power grid.
Features:
- Measure all kinds of meter, include single phase (1P2W) meter, three phase three wiremeter (3P3W), three phase four wire meter (3P4W) etc
- Measure the current with clamp CT and terminal two mode.
- Measure Vrms, Irms, phase angle, active power, reactive power, apparent power of three phase or single phase
- Measure total active power and total reactive power of three phase;
- Measure phase angle
- Measure frequency of power grid
- Display vector diagram
- Display waveform of voltage and current
- Analyze and display 2nd – 51st harmonic of voltage and current at real time
- Energy accumulating test (Dial test)
- Auto-check external wiring correct or not
- Test ratio of current transformer in low voltage circuit
- Wiring emulation, can simulate all kind of wirings on site without input voltage and current
- Realtime clock, accurate record testing time
- Store, browse and transfer measured data
- Real-time measured data by PC, and download calibration parameter
- Two kinds of power supply way: external AC power and voltage test lead power
- Support the barcode scanner to input number of energy meter automatically (option)
Main specifications:
| KE7302 | Voltage measurement | Voltage range | 3 x (0V – 480V) | Accuracy | ±0.1% | Harmonics | 2nd- 51st | Current measurement | Current range | Terminal input | 0.1A – 10A | Clamp input | 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A | Accuracy | Terminal input | ±0.2% | Clamp input | ±0.2%(5A), ±0.5% (others) | Harmonics | 2nd- 51st | Accuracy of power measurement | Active power | Terminal input | ±0.2% | Clamp input | ±0.2%(5A), ±0.5% (others) | Reactive power | Terminal input | ±0.2% | Clamp input | ±0.2%(5A), ±0.5%(others) | Accuracy of energy measurement | Active energy | Terminal input | ±0.2% | Clamp input | ±0.2%(5A), ±0.5%(others) | Reactive energy | Terminal input | ±0.2% | Clamp input | ±0.2%(5A), ±0.5%(others) | Phase measurement | Phase range | 0 -- 360° | Accuracy | ±0.1° | Frequency measurement | Frequency range | 45Hz – 65Hz | Accuracy | ±0.05Hz | Pulse output | Low frequency output(CL) | 3600imp / kWh | Ppulse input | Input channel | 1 | Input frequency | Max. 100Hz | Others | Power supply | Build-in rechargeable battery, external power supply, power through the tested terminal | Dimensions | 214mm×150mm×50mm | Weight | 1.3kg | |