Three Phase Reference Standard Meter on-site meter tester with clamp CT class0.05
KE7308 Three Phase Reference Standard Meter
Accuracy : 0.05, Test method: clamp CT and 20A terminal input. It's light and small, which is convenient for on-site test. And it can be used to test the error of three phase energy meters and field electrical parameters of power grid. With a IP67 protection level, it can be used in many harsh condition.
Features:
- Wide current range (direct connection): 0.05 A to 20A, the highest accuracy of each test point is 0.05%
- Calibrate the error of all electricity energy meters, checking the constant of the energy meter
- Simultaneous checking of the primary meter and the secondary meter in the same loop, or simultaneously checking of the active power meter and reactive power meter in the same loop
- 7” color LCD display, All the parameters of each operation function can be displayed within one page
- Two operation modes: touch screen and keyboard. Easy and reliable operation..
- Measure voltage, current,frequency, power, power factor and phase angle
- Simultaneous measure and display waveforms of three phase voltage and current
- Measure ratio of CT.
- Allocate clamp of 20A, 100A, 200A, 500A,1000A to directly measure the comprehensive error
- Measure the 2nd - 51st harmonics of current and voltage
- Display vector diagram, judge the wiring right or wrong automatically
- Industrial grade engineering plastic suit case, which has a safety protection level of up to IP67.
- Read the information of energy meter with barcode scanner (optional)
- Battery, test lead power or external power for choices
- Communicate with PC, download calibration data through USB flash disk, RS-232 port
- Firmware can be upgraded through removed disk by users themselves
- Save and browse the testing data
Main specifications:
Voltage measurement
Voltage range 3 x (10V – 480V)
Accuracy ±0.05%
Harmonics 2nd- 51st
Current measurement
Current range Terminal input 0.05A – 20A
Clamp input 5A, 20A, 100A, 500A, 1000A, 1500A
Accuracy Terminal input ±0.05%
Clamp input ±0.2%(5A), ±0.5% (others)
Harmonics 2nd- 51st
Accuracy of power measurement
Active power Terminal input ±0.05%
Clamp input ±0.2%(5A), ±0.5% (others)
Reactive power Terminal input ±0.05%
Clamp input ±0.2%(5A), ±0.5%(others)
Accuracy of energy measurement
Active energy Terminal input ±0.05%
Clamp input ±0.2%(5A), ±0.5%(others)
Reactive energy Terminal input ±0.05%
Clamp input ±0.2%(5A), ±0.5%(others)
Phase measurement
Phase range 0 -- 360°
Accuracy ±0.1°
Frequency measurement
Frequency range 45Hz – 65Hz
Accuracy ±0.05Hz
Pulse output
Low frequency output(CL) 36000 imp / kWh
Ppulse input
Input channel 2
Input frequency Max. 100Hz
Others
3 Power supply method:
Build-in rechargeable battery,
external power supply,
power through the tested terminal
Dimensions 323mm×275mm×135mm
Weight 3.5kg