UL 1072 Standard 100 % Insulation 500mcm XLPE Insulation PVC Sheath Power Cable APPLICATIONS URD - TRXLPEMLPE insulated cables are designed and manufactured to meet the applications of primary underground distribution suitable for use in wet or dry location, direct burial, underground duct, and exposed to sunlight, To be used at 15kV upto 35kV at conductor temperatures not to exceed 90 deg. C for normal operation. SPECIFICATIONS TRXLPEMLP insulated URD cables meets or exceeds all applicable requirements of thefollowing standards, and guaranteed all cables manufactured and tested under this standards. - ANSIIICEA S94-649 - AEIC CS-8 - ASTM B-3, ASTM B-8, ASTM B-230 & ASTM B-231 CONSTRUCTION Conductor : Bare aluminium or copper, stranded class B compressed stranding Conductor Shield :Extruded semi-conducting compound Insulation : TRXLP (TreeRetardant XLPE) or XLPE Insulation Shield : Extruded semi-conducting compound Concentric Neutral : Uncoated copper concentric neutral wires (coated copper are optional) Encapsulated Jacket : Non-conducting LLDPE embedded jacket with extruded red stripes. PVC or Semi-conducting jacket are available upon request Data sheet: Condctor | Copper Neutral (1/3) | diameter(inch) | | Weight (Pounds) |
AWG orMCM | Stranding | Number of Wires | Size AWG (Solid) | Conductor | Over | Over Insul. | Over Neutral | Over | Conductor | Concentric | TotalNo | Total WithJacket |
Insulation | Shield | Wires | Encaps. Jkt. | Neutral | Jacket |
1/0 | 19 wire | 9 | 14 | 0.37 | 1.12 | 1.23 | 1.35 | 1.46 | 325.8 | 119.2 | 659 | 4926 |
2/0 | 19 wire | 11 | 14 | 0.42 | 1.17 | 1.27 | 1.40 | 1.50 | 410.9 | 146.3 | 775 | 808 |
3/0 | 19 wire | 14 | 14 | 0.47 | 1.22 | 1.32 | 1.48 | 1.59 | 518.1 | 185.9 | 900 | 923 |
4/0 | 19 wire | 11 | 12 | 0.53 | 1.28 | 1.38 | 1.54 | 1.71 | 653.3 | 228.0 | 1110 | 1055 |
250 | 37 wire | 13 | 12 | 0.57 | 1.33 | 1.44 | 1.64 | 1.81 | 771.9 | 282.1 | 1330 | 1292 |
350 | 37 wire | 12 | 10 | 0.68 | 1.44 | 1.54 | 1.70 | 1.89 | 1081 | 398.0 | 1633 | 1519 |
500 | 37 wire | 17 | 10 | 0.81 | 1.57 | 1.72 | 1.88 | 2.04 | 1544 | 543.5 | 2002 | 1886 |
750 | 61 wire | 25 | 10 | 0.99 | 1.76 | 1.93 | 2.11 | 2.28 | 2316 | 801.5 | 2650 | 2289 |
1000 | 61 wire | 33 | 10 | 1.14 | 1.92 | 2.06 | 2.27 | 2.43 | 3088 | 1058 | 3847 | 2960 |
Other related cables you may interested
DLO cable,RHH/RHW/RHW-2/XHH/XHHW/XHHW-2/SIS, THHN/THHW/THW/THW-2/THWN/THWN-2/TW,SER/SEU/USE/USE-2/MHF, MV-90/MV-105,TC cable,MC cable,DLO,type DG,PV wire,AC Cable,Soow,Welding cable and so on ------Our Feature------
- Imported equipment with experienced technical team
The company have three plant and has 3048 employees which have 206 engineers. Plant has a series of imported production lines including Niehoff copper drawing lines, Troster Germany and Maillefer Finland 500KV VCV lines, stranding machine from Pourtier France, SKET Germany, Caballe Spain, 220KV and 35KV production line plus SIKORA X - RAY 8000 on-line eccentricity measuring unit from Germany - Complete certification system
Qifan Cable have gotten ISO 9001, ISO 14001, OHSAS 18001. Plant passed TUV, VDE, UL, CE, SAA, BS etc. certificate. - Perfect Production system
Qifan Cable products cover LV power cable, MV power cable, HV&EHV power cable, ABC cables, ACSR/AAC/AAAC/ACAR/OPGW ,submarine cable, control cable, instrumentation cable, building wire, flexible rubber cable, fire rated cable, renewable cable, solar cable, industrial cable, Lan cable, coaxial cable etc. - Perfect Sales service system
Qifan Cable can offer the OEM/ODM service, Multiple products, Skilled Export sale engineer team, Reasonable price, Reliable quality, Friendly service. Qifan is always your best choice.

--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
UL 1072 Standard 100 % Insulation 500mcm XLPE Insulation PVC Sheath Power Cable
UL 1072 is a standard developed by Underwriters Laboratories (UL) that covers medium voltage cables for use in power distribution systems. The standard specifies the construction, materials, and testing requirements for these cables to ensure their safe and reliable operation.
"100% insulation" refers to the insulation material used in the cable, which is expected to provide complete coverage and protection for the conductors. In the case of 500mcm XLPE (cross-linked polyethylene) insulation, it means that the insulation layer completely surrounds the conductors, leaving no exposed areas.
XLPE is a commonly used insulation material for medium voltage power cables. It offers excellent electrical properties, thermal resistance, and moisture resistance, making it suitable for various applications.
The "PVC sheath" refers to the outer protective layer of the cable. PVC (polyvinyl chloride) is a durable and cost-effective material used for cable sheathing. It provides mechanical protection, as well as resistance to chemicals, sunlight, and abrasion.
Overall, a power cable with 100% insulation and 500mcm XLPE insulation with a PVC sheath, in compliance with UL 1072, would be designed for medium voltage power distribution, offering reliable electrical insulation, mechanical protection, and environmental durability.