YHY-13506000 13.5V 6A External Desktop Power Supply KC UL CE FCC Car Cigarette Lighter Plug for Portable refrigerators
Meet Efficiency Level VI requirements
Universal AC Input / Full range 100-240V
No Load power consumption ≤0.21W
2-3 pole AC Inlet IEC320-C14/C8/C6
Class I Power
Protection:Short circuit/ Overload
Fully enclosed plastic case
LED indicator (Blue) for power on
The purpose of the document is to specify a Single phase AC Input, Single output switching power supply, This product is AC to DC switching power transfer device, it can provide for a 13.5v, 6A max & 80W max DC Output with constant voltage source. This Specification defines the input, output , performance characteristics, environment, noise and safety requirement for a power supply.
DC Cable 16AWG 0.5M / DC Jack,inside“+” ,outside “-”
Caution
Using indoor only!
Transport
cars, boats, planes transportation, transportation should be canopies, sunscreen, civilization loading and unloading.
Storage
should be stored in the box when not use, warehouse environment for-20 °C ~ + 60 °C, relative humidity 10% ~ 95%, and warehouse not allow to have the harmful gas, or inflammable or explosive products and corrosive chemicals, no strong mechanical vibration, impact and strong field, packing boxes from at least 20 cm high, the distance from the wall, heat source, window or air entrance at least 50 cm, in this stated conditions storage period generally is 2 years, more than 2 years should be inspection.
Specifications | ||
Input Voltage Range | VAC | 100-240Vac 50/60Hz |
Inrush Current at 110VAC, 25℃ | A | 30A |
Input Current(Max) | A | 2.0A(100VAC Input) |
Power Factor | - | Meets EN61000-3-2 |
Leakage Current(220VAC 60Hz) | mA | 0.25MA |
Hold Up Time at 110VAC input, full load | ms | 5 |
Temperature Coefficient | ℃ | ±0.05%/℃ |
Voltage Accuracy | % | ±2% |
Adjustment Range | - | None |
Min. Load | A | None |
Total Regulation | - | ±5% |
Ripple & Noise | mV | 120mV |
Short Circuit Protection | % | Continuous - hiccup mode |
Over Voltage Protection | ℃ | 110-150% of nominal (Cycle input power to reset) |
Efficiency at Average Load | - | 88% min |
Operation Temperature | - | 0 to +60℃, derating linearly to 50% load above 40℃ |
Storage Temperature | - | -10 to +85℃ |
Humidity (non condensing) | - | 10-90% RH |
Cooling | - | Convection |
Withstand Voltage | - | Input to Ground 1.5kVAC, Input to Output 3kVAC (Output is connected to Ground) |
Vibration (non condensing) | - | 23.52m/s2 (10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour) |
Shock | - | < 196.1 m/s2 (20G) |
Safety Agency Certifications | - | UL60950-1, EN609501-1, IEC60950-1, CE Mark |
DOE Regulation | - | VI |
Off-Load Power Consumption | mW | <210mV |
Conducted & Radiated EMI | - | EN55023-B, FCC Class B |
Immunity | - | EN55024 |
Weight | G | 480g |
Size(WxLxH) | mm | 140x60x30mm |
Cable Length and Thickness | mm | 1200mm |
AC Input Connector | - | IEC 320-C6/C8/C14 |
Output Connector | mm | 5.5x2.1mm (Accept more request) |
MTBF 100%, 25℃ | Hours | 50,000 hours |
Warranty | Years | 3 years |
Output Ratings | ||||
Model | Output (V) | Output Max. (A) | Power Max. (W) | DOE VI |
YHY-09008000 | 9 | 8 | 72 | √ |
YHY-10008000 | 10 | 8 | 80 | √ |
YHY-12007500 | 12 | 7.5 | 90 | √ |
YHY-15006000 | 15 | 6 | 90 | √ |
YHY-18005000 | 18 | 5 | 90 | √ |
YHY-19004700 | 19 | 4.7 | 90 | √ |
YHY-20004500 | 20 | 4.5 | 90 | √ |
YHY-24003700 | 24 | 3.7 | 90 | √ |