Specifications
Brand Name :
HNMC
Model Number :
MCGB001
Place of Origin :
China
MOQ :
1
Payment Terms :
Western Union, MoneyGram, L/C, T/T
Delivery Time :
4-8weeks
Packaging Details :
wooden package
Device flow range :
0.06 m3/h~40m3/h
Total uncertainty :
≤0.5% , k=2
Test range of absolute pressure sensor :
0~120kPa, Accuracy ≤0.075%
ambient temperature :
(20±5)℃
relative humidity :
(45~75)%RH
test range of temperature sensor :
(0—50)℃
accuracy :
≤±0.2℃
test range of humidity sensor :
0~100%RH
Description

0.016 m3/h~6 m3/h Gas Meter Test Bench (commercial gas meter)

Technical Proposal

Feature

  • Adopt Serial comparison method to test several different kinds of diaphragm gas meter.
  • Use VSBA Sonic nozzle to meet Qmax,0.2Qmax,Qmingas meter flow point measurement. It is convenient to change and clean nozzle regularly. (patent No.:20110237008.6)
  • Could accurately test temperature, pressure etc. and calculate error in time, guarantee device stable and accurate Ø
  • Adopt negative pressure method to ensure gas flow passed through to reach Critical flow state.
  • Test system could test automatically under control of PC software, meanwhile could save, print, analyze and statistic etc.
  • Also test manually gas meter without cursor .
  • graceful appearance, fine art-work,durable structure

0.016 m3/h~6 m3/h Gas Meter Test Bench (commercial gas meter)

Gas Test bench configuration unit and work principle

Gas Test bench is consist of compression gas source,vacuum bump, control gas circuit, test pipe system,VSBA Sonic nozzle, device running control system, error running system, operation platform and PC etc

Gas flow by vacuum pumping in test pipeline. When gas trough sonic nozzle reach critical flow condition,quality and flow of gas though tested meter and nozzle keep the same. Control and operation part work by electric. Mainly consist of error sampling calculation CPU,device running CPU and PC .

0.016 m3/h~6 m3/h Gas Meter Test Bench (commercial gas meter)

Main technical index and performance of 12 positions Sonic nozzle

Main technical index and performance of Sonic nozzle gas flow verification device (commercial gas meter)

Device flow range 0.06 m3/h~40m3/h
Total uncertainty ≤0.5% , k=2
Negative pressure
Test range of absolute pressure sensor 0~120kPa,Accuracy ≤0.075%
Work condition
ambient temperature (20±5)℃
relative humidity (45~75)%RH
test range of temperature sensor (0—50)℃
accuracy ≤±0.2℃
test range of humidity sensor 0~100%RH
Gas meter Spec G6~G25
Installation method clip meter by pneumatic method,test 1-2 nos meter(diaphragm meter) for serial test. Up to G10 for 2 positions,G25 or bigger is single position .Clip meter by volumetric structure only support flow gauge of DN25,DN40 meter. If it other diameter flow gauge, it will match other nozzle
Sampling method collect automatically or manual reading input, data dealing automatically, record save, certificate and test report print, data inquiry
Micro differential pressure sensor test range 0~1000Pa,accuracy≤0.5%
XO frequency accuracy of time record <10-4,stability per day<10-5.Flow point:0.06m3/h,0.1 m3/h,0.25 m3/h ,0.4 m3/h ,1 m3/h,2 m3/h,4 m3/h,8 m3/h,16m3/h,32 m3/h,flow point deviation≤5%
Power supply AC 3*380V±20V ,50Hz

Test pipeline system as below picture:

6m3/h Gas Meter Test Bench Adopting Negative Pressure Method

Send your message to this supplier
Send Now

6m3/h Gas Meter Test Bench Adopting Negative Pressure Method

Ask Latest Price
Brand Name :
HNMC
Model Number :
MCGB001
Place of Origin :
China
MOQ :
1
Payment Terms :
Western Union, MoneyGram, L/C, T/T
Delivery Time :
4-8weeks
Contact Supplier
6m3/h Gas Meter Test Bench Adopting Negative Pressure Method
6m3/h Gas Meter Test Bench Adopting Negative Pressure Method
6m3/h Gas Meter Test Bench Adopting Negative Pressure Method

Zhengzhou Great Electric Co.,Ltd.

Active Member
5 Years
henan, zhengzhou
Since 2009
Business Type :
Manufacturer, Distributor/Wholesaler, Seller
Total Annual :
100-500
Employee Number :
8 ~10
Certification Level :
Active Member
Contact Supplier