Typical Time-to-Trip Charts at 25℃
Electrical Characteristic

Electrical Specifications:
Ihold=Hold current: maximum current device will not trip in 25℃ still air.
Itrip= Trip current: minimum current device will always trip in 25℃ still air.
Vmax=Maximum voltage device can withstand without damage at rated current(Imax).
Imax=Maximum fault current device can withstand without damage at rated voltage(vmax).
Pd max= Power dissipated when device is in the tripped state in 25℃ still air environment at rated voltage.
Max Time-to-trip=Maximum time to trip(s) at assigned current.
Rmin=Minimum device resistance prior to tripping at 25℃.
Rmax=Maximum device resistance prior to tripping at 25℃.
R1max=Maximum device resistance one hour after it is tripped at 25℃