3.5-10.5KW Cooling Capacity Micro Data Center Rack Mountable
Product Introduction
Ranging in size from a single 19-inch rack to a 40-foot shipping container, micro data centers are small enough to be deployed in locations where a traditional data center would be impractical. This allows organizations to solve the low-latency data processing and storage challenge in a cost-effective way. While there is no single standard for micro data center design, an MDC must be able to house the full technology stack an application requires. As a result, these components are common in MDCs | ![]() |
Advantages
![]() | By bringing data processing closer to end-users and enabling organizations to distribute their data center footprint, MDCs deliver several business benefits including:
Low latency This is the fundamental issue MDCs help address. By bringing the “client” and “server” computers geographically closer, MDCs can lower latency significantly.
A failure, such as a cut MPLS (Multiprotocol Label Switching) line, that leads to a traditional data center becoming inaccessible can bring production to a halt. Even if fault tolerance is part of the design, it’s often N+1 or 2N at best. With MDCs, having dozens of failover options becomes feasible.
Often, micro data centers can be shipped partially or fully assembled. Additionally, because their small size makes accessing adequate space and power easier, MDC provisioning is significantly faster than a traditional data center build-out.
By enabling a standardized and repeatable design, MDCs can reduce opex and maintenance costs.
Micro data centers allow businesses to incrementally scale up based upon demand. This allows for a more elastic and agile approach to infrastructure that is conducive to rapid growth. |
Application
| |
Technical Parameter
Model | EC08 | EC12 | EC20 | ERx |
Power | 3KVA | 3-6KVA | 6-30KVA | |
Number of cabinets | 0.8m high cabinet, available space 8U | 1.2m high cabinet, available space 16U | Standard 42U cabinet, free space 30U | 2-10 standard 42U glass door cabinets |
Enclosed cabinet | Glass door, IP5X, full cold and hot channel sealing | |||
Power supply | 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection | 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection | 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection | |
Refrigeration | Unique air duct design, without air conditioner and outdoor unit | Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | |
Monitor | 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display | 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring | 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring |