Inter-row air conditioner for cooling the computer room
Product Introduction
In-row air conditioners are also called in-row air conditioners, or in-row refrigeration units, which are precision cooling systems specially designed for high heat density racks.In the design of the air conditioner in the computer room between rows, the cold air is supplied from the cold aisle and then returned from the hot aisle, which completely solves the problem of short circuit of the hot and cold air flow, ensures the uniform temperature of the server cabinet, and eliminates local hot spots , thereby increasing the operational reliability of the server and effectively reducing unnecessary energy consumption. | ![]() |
Advantages
![]() | Efficient - save money and space ● Adopt high-efficiency EC fan, with soft-start function, multiple fans are evenly distributed, air flow is uniform without dead angle, and heat exchange efficiency is improved ● The fan adopts hot-swappable design, which is easy to maintain, ensuring high efficiency and energy saving, and achieving redundancy ● The outdoor unit fan adopts variable frequency stepless speed regulation control, energy saving, noise reduction and long service life High intelligence - time saving ● Standard RS485 communication interface to realize remote monitoring, optional SNMP and TCP/IP interface to improve the efficiency of communication interconnection and meet users' various needs for energy linkage, monitoring and inspection, etc. ● Rich alarm and protection functions in the system, support up to 18 remote temperature sensors, good temperature control technology ● Easy networking to optimize cost and time High reliability - no worry ● Adopt DC inverter compressor, dynamic cooling, adapt to the rapidly changing heat load of the machine room, reduce the frequent start and stop of the compressor, and improve the system reliability ● Fan online hot-swappable and redundant design, easy to maintain, ensure high efficiency and energy saving while achieving redundancy to protect equipment from running continuously |
Technical Parameter
Model | CRA013A | CRA020A | CRA040A | CRA050A | CRA060A |
Air supply | Front/Side | Front/Side | Front | Front | Front |
Power supply | 380VAC/3Ph/50Hz | ||||
Cooling capacity-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Sensible cooling-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Compressor | |||||
Refrigerant | R410A | ||||
Quantity | 1 | ||||
Fan | |||||
Fan type | EC Centrifugal fan | ||||
Quantity | 4 | 5 | 2 | 3 | 3 |
Air volume-m3/h | 3200 | 5000 | 8800 | 11000 | 12500 |
Heater | |||||
Heat type | PTC | ||||
Capacity-KW | 2 | 3 | 6 | 6 | 6 |
Humidification | |||||
Capacity-KW | 1 | 1.5 | 3 | 3 | 3 |