Security Smart PDU with detection function
Product Introduction
COOLNET intelligent power distribution products are widely applied in the communication industries,Security system,IDC engine room,Electric power system,Track traffic,etc.They support security protection for the critical electronic equipment in computer room,information center,security monitor and control,and automated industrial productionline.They are also widely applied applied in the industry of office cabling,intelligent building etc. | ![]() |
Advantages
![]() |
|
Functions
Energy Monitoring Function It can provide abundant functions such as energy usage, efficiency and environmental monitoring in data center etc. The input voltage and current of each circuit can be measured by intelligent PDU, and the usage of power can be calculated in watts or kilowatts. The total energy usage can be calculated, from which the operators of data center decide whether they need to add PDU or not. Environmental Monitoring Function Environmental monitoring and management can be carried out through the existing data center LAN by new generation of intelligent PDU. Intelligent PDU integrates multiple temperature and humidity/moisture sensors. Intelligent PDU can track environmental factors and issue warning timely. In addition, the administrator can also compare the environment data with the energy consumption data to confirm the energy consumption of the server, and inspect actual effect of the temperature control measures for inner rack.
Centralized Management and Data Analytic Statistics Intelligent PDU can be managed and accessed uniformly by centralized management platform, realize group management, access right management, data report generation, micro environment prediction, etc for all the PDU within the data center. | ![]() |
Parameter
PDU |
Parameters | |
input | Input type | AC single phase, AC three phase,-48VDC,240VDC,336VDC |
Input mode | Transparent open type junction box,power cord, cable, industrial connector, socket etc. | |
Input voltage range | 100-277VAC/312VAC-418VAC/11VDC-240VDC/-43VDC- -56VDC | |
AC input frequency | 50/60Hz | |
total load current | MAX 63A | |
Output | Storage temperature | -40 - +70 |
Relative humidity | 5-95% (No condensation) | |
Atmospheric pressure | 70kPa - 106kPa | |
Working altitude | No more than 4000M | |
Environmental | Working temperature | -10 - +75 |
Storage temperature | -40 - +80 | |
Relative humidity | 5-95% (No condensation) | |
Working altitude | No more than 4000M | |
IP rating | IP20 | |
Protection | input protection module | Circuit breaker, lightning protection, leakage protector, temperature insepction module (optional) |
Output protection module | Circuit breaker, fuse box, fuse(optional) |
Installation method
Certification
Case
Factory