PDU to ensure the safety of electricity in the computer room
Product Introduction
COOLNET PDUs can be used to input AC or DC high power AC power, equipped with high power air switches, output single or multiway grouped sockets, one PDU can meet the needs of the entire cabinet power distribution equipment, custom vertical type installation 0U, does not occupy space, easy to install, safe, stable, beautiful appearance, and can be combined with a variety of modules. A variety of modules can be combined, the wiring method is open junction box wiring, wiring is convenient, reduce installation time, access to the input line will not be due to loose wire and lead to high temperature rise, junction box with temperature rise alarm (optional) can be timely detection of temperature rise abnormalities at the junction, circuit breaker (optional) protection cover using the sliding cover type, when using does not occupy the operating space, current, voltage, power monitoring module (optional) with USB interface for access to temperature and humidity sensors, hot-swappable modules for better maintenance. | ![]() |
Advantages
![]() |
|
Functions
Energy Monitoring Function It can provide abundant functions such as energy usage, efficiency and environmental monitoring in data center etc. The input voltage and current of each circuit can be measured by intelligent PDU, and the usage of power can be calculated in watts or kilowatts. The total energy usage can be calculated, from which the operators of data center decide whether they need to add PDU or not. Environmental Monitoring Function Environmental monitoring and management can be carried out through the existing data center LAN by new generation of intelligent PDU. Intelligent PDU integrates multiple temperature and humidity/moisture sensors. Intelligent PDU can track environmental factors and issue warning timely. In addition, the administrator can also compare the environment data with the energy consumption data to confirm the energy consumption of the server, and inspect actual effect of the temperature control measures for inner rack.
PDU Access and Network Function Intelligent PDU can be connected through the LAN form, and be flexibly managed through a Web browser or command line interface (CLI).lt makes the administrator easily access the data, for real-time monitoring. | ![]() |
Parameter
PDU |
Parameters | |
input | Input type | AC single phase, AC three phase,-48VDC,240VDC,336VDC |
Input mode | Transparent open type junction box,power cord, cable, industrial connector, socket etc. | |
Input voltage range | 100-277VAC/312VAC-418VAC/11VDC-240VDC/-43VDC- -56VDC | |
AC input frequency | 50/60Hz | |
total load current | MAX 63A | |
Output | Storage temperature | -40 - +70 |
Relative humidity | 5-95% (No condensation) | |
Atmospheric pressure | 70kPa - 106kPa | |
Working altitude | No more than 4000M | |
Environmental | Working temperature | -10 - +75 |
Storage temperature | -40 - +80 | |
Relative humidity | 5-95% (No condensation) | |
Working altitude | No more than 4000M | |
IP rating | IP20 | |
Protection | input protection module | Circuit breaker, lightning protection, leakage protector, temperature insepction module (optional) |
Output protection module | Circuit breaker, fuse box, fuse(optional) |