The Precision Air Conditioning Units are meticulously designed for critical environments that demand high precision temperature and humidity control. These state-of-the-art units are an ideal solution for data center environmental monitoring, ensuring that sensitive equipment operates within optimal climatic conditions. As a product classified under Precision Air Conditioning, these units offer unparalleled accuracy in climate control, which is vital for the protection and longevity of sensitive electronic equipment. With precise control over temperature and humidity, these units play a critical role in a data center temperature monitoring system. They help to prevent equipment failure due to overheating or humidity issues, which can result in costly downtime and potentially damage critical data. | ![]() |
![]() |
|
Advantages
|
|
Model CHS | 03-10 | 06-30 | 10-20 |
Air supply | F/U | F/U | F/U |
power supply | 220Vac/1Ph/50Hz | 380Vac/3Ph/50Hz | 380Vac/3Ph/50Hz |
Fan | |||
Fan Type | EC Centrifugal Fan | ||
Fan Quantity | 1 | 1 | 1 |
Excess Pressure Outside (Pa) | Standard Pressure is 20pa Adjustable From 0-50pa | ||
Compressor | |||
Compressor Type | Rotary | Scroll | Scroll |
Refrigerant | R410A | ||
Compressor Quantity | 1 | 1 | 1 |
Dehumidifier | |||
Dehumidification Capacity (L/24h) | 80 | 160 | 240 |
Dehumidification Air Volume (m³/h) | 1300 | 1900 | 2500 |
Dehumidification power (KW) | 1.8 | 2.96 | 3.96 |
Humidifier | |||
Type | Wet Film Humidifier | ||
Humidification capacity (kg/h) | 10 | 20 | 20 |
Humidification Air Volume (m³/h | 3000 | 5000 | 5000 |
Humidification Power (KW) | 0.8 | 1.4 | 1.4 |
Humidification Parameters | |||
Type | Thermal Expansion Valve | ||
Air Filter | G4 Plate Fliter | ||
Indoor Unit Noise dBA | 63 | 66 | 66 |
Unit Connection Pipe | |||
Water Filling Method | Automatic | ||
Drainage Method | Automatic | ||
Water Filling Pipe (DN) | 15 | 15 | 15 |
Drainage Pipe (DN) | 20 | 20 | 20 |
Electrical Parameters | |||
Maximum Operating Current (A) | 16 | 11 | 14 |
Power Cable (mm²) | 3*2.5 | 5*2.5 | 5*2.5 |
Indoor Unit Structure Parameters W*D*H (mm) | |||
Dimension | 990*900*2000 | ||
Weight(kg) | 220 | 240 | 240 |
The Coolnet CHS SERIES is particularly suitable for data centers where a reliable data center temperature monitoring system is crucial. These precision air conditioning units are designed for floor standing mounting, which makes them versatile and easy to integrate into existing server rooms or new designs. The centrifugal EC FAN in the fan section ensures efficient and quiet operation, maintaining a constant temperature and humidity air conditioner environment that meets the stringent requirements of sensitive electronic equipment.
For scenarios where constant vigilance over environmental conditions is necessary, such as server rooms, telecommunications facilities, and other technical spaces, the Coolnet CHS SERIES excels. Its capability to provide a stable climate makes it indispensable as a part of a comprehensive data center temperature monitoring system. The precise control of humidity and temperature not only safeguards the hardware but also ensures optimal performance of the equipment housed within.
In conclusion, the Coolnet CHS SERIES Precision Air Conditioning Units are an essential investment for any operation that values data integrity, equipment longevity, and operational continuity. Their advanced features, coupled with dependable after-sales support, make them the smart choice for professionals looking to maintain their facilities at the zenith of efficiency and reliability. | ![]() |