Product Description
The Precision Air Conditioning Units are meticulously designed to cater to the demanding requirements of data centers and other critical environments, where maintaining constant temperature and humidity is paramount. One of the primary applications of these units is as Data Center Constant Humidity Equipment. Data centers and server rooms are environments where electronic equipment is extremely sensitive to fluctuations in humidity. Excessive humidity can lead to condensation, which in turn can cause corrosion or short circuits in electronic components. Conversely, too little humidity can lead to static electricity buildup, also posing risks to sensitive equipment. The Precision Air Conditioning Units address these challenges by maintaining the optimal humidity levels required for the safe and efficient operation of data center equipment. | ![]() |
|
|
Technical Parameters
Model CHS | 03-10 | 06-30 | 10-20 |
Air supply | F/U | F/U | F/U |
power supply | 220Vac/1Ph/50Hz | 380Vac/3Ph/50Hz | 380Vac/3Ph/50Hz |
Fan | |||
Fan Type | EC Centrifugal Fan | ||
Fan Quantity | 1 | 1 | 1 |
Excess Pressure Outside (Pa) | Standard Pressure is 20pa Adjustable From 0-50pa | ||
Compressor | |||
Compressor Type | Rotary | Scroll | Scroll |
Refrigerant | R410A | ||
Compressor Quantity | 1 | 1 | 1 |
Dehumidifier | |||
Dehumidification Capacity (L/24h) | 80 | 160 | 240 |
Dehumidification Air Volume (m³/h) | 1300 | 1900 | 2500 |
Dehumidification power (KW) | 1.8 | 2.96 | 3.96 |
Humidifier | |||
Type | Wet Film Humidifier | ||
Humidification capacity (kg/h) | 10 | 20 | 20 |
Humidification Air Volume (m³/h | 3000 | 5000 | 5000 |
Humidification Power (KW) | 0.8 | 1.4 | 1.4 |
Humidification Parameters | |||
Type | Thermal Expansion Valve | ||
Air Filter | G4 Plate Filter | ||
Indoor Unit Noise dBA | 63 | 66 | 66 |
Unit Connection Pipe | |||
Water Filling Method | Automatic | ||
Drainage Method | Automatic | ||
Water Filling Pipe (DN) | 15 | 15 | 15 |
Drainage Pipe (DN) | 20 | 20 | 20 |
Electrical Parameters | |||
Maximum Operating Current (A) | 16 | 11 | 14 |
Power Cable (mm²) | 3*2.5 | 5*2.5 | 5*2.5 |
Indoor Unit Structure Parameters W*D*H (mm) | |||
Dimension | 990*900*2000 | ||
Weight(kg) | 220 | 240 | 240 |
Applications
The application occasions and scenarios for the Coolnet precision air conditioning units are diverse, yet they are particularly indispensable in settings where a data center temperature monitoring system is crucial. These units cater to the demanding needs of data centers, server rooms, and telecommunications facilities, where stable environmental conditions are vital for the optimal performance and longevity of sensitive electronic equipment. The precision air conditioning ensures the consistency of both temperature and humidity, creating an ideal atmosphere for technological assets.
Furthermore, the Coolnet CHS SERIES is an ideal solution for data center environmental monitoring, as it integrates seamlessly with existing building management systems, providing real-time feedback and control over the climate within the facility. The precision air conditioning units are also suitable for use in medical laboratories, clean rooms, and any other areas where environmental conditions must be strictly controlled to ensure the integrity of processes and products. | ![]() |