Integrated Prefabricated Data Center, Shipping Containerized Data Center For USA Market
Coolnet I-container series is a prefab integrated outdoor data center infrastructure solution that integrates functions such as power supply and distribution, temperature control, cabinets, management, fire protection, lightning protection and grounding. One-stop professional service solves a large number of construction preparation and outsourcing problems for customers, and is the best solution to meet the fast and flexible needs of enterprise-level data centers. Applicable to multiple industries and scenarios, it has minimalist, green, intelligent and safe features.
The internal components of the container data center include: cabinets, power distribution cabinets, UPS, batteries, air conditioners, fire protection, security and monitoring systems.
Container size: standard 20ft/40ft or non-standard customized size.
Feature
Low PUE, can save a lot of power resources, reduce power consumption, reduce carbon emissions, energy saving and environmental protection.
The bottom of the container is equipped with a support, and the bottom is sealed to effectively prevent the impact of water accumulation on the container. Containers can withstand harsh climates with high security guarantees.
The in-row air conditioner is close to the heat source, and the cold aisle/hot aisle is closed, which can avoid the loss of cooling capacity caused by the mixing of cold and hot air, and water cooling.
Intelligent management system, 3D visual monitoring, near-end PAD management function, support customized mobile APP management function, unattended computer room.
Customer value
Easy of location
Not limited by climatic and geographical conditions, portable data center can be deployed in difficult areas. Relocation is flexible.
Rapid deployment
It takes 2-3 years for a traditional data center to be built, while a new generation of modular data center takes only 2-3 months, it can be used when plugged in.
Low construction cost
Traditional data centers have a long construction period and require high starting capital. The capital cost of prefab data center construction is much lower than that of traditional data centers.
PRODUCT PARAMETERS | ICDC-20 | ICDC-20 |
Container Size | 20’HQ | 40’HQ |
Rack Specification | 600*1000(1100)*2000mm | 600*1000(1100)*2000mm |
Single Rack Capacity | 42U | 42U |
Rack Quantity | 4PCS | 8-10PCS |
Single Rack Capacity | 3-10KW | 3-10KW |
IT Equipment Total Capacity | 12-30kw | 24-75KW |
UPS | 25kva*2 N+1 modular UPS | 25kva*4 N+1 modular UPS |
Battery back up time | 5-15mins | 5-20mins |
Cooling | In-row air conditioner | In-row air conditioner |
Monitoring system | YES | YES |
Door Security System | YES | YES |
Fire alarm and gas fire extinguishing system | YES | YES |
Video Monitoring System | YES | YES |
EPO | YES | YES |
Transportability | Support | Support |
Stackable | Support | Support |
Application | Outdoor Type | Outdoor Type |
Diesel Generator Module | Extraposition | Extraposition |
Applications
Enterprise: Small Data Center
Operator: Small IT room, small IDC, DR room and edge DC
Government: Smart City, Safe City Data Center
Education: University/Institute Data Center
Energy: Production/Investigation Field Data Center
Finance: Backup data center
Transportation: Airport/Railway/Port without housing power supply and distribution