Cyber Master Close Control Unit Air Conditioner With High Quality Control Components
Product Introduction
CyberMaster series pracision air conditioning system adopts international cutting-edge constant temperature and conslant_humidity technology, which is designed and developed for precision environment. This series products dedicated to equipments with high precision control requirements of temperature, humidity and cleanliness and requires equipment continuously opertaion 24 hours*265 days.
Benefits | ![]() |
Product functions
![]() | Fault detection and alarm functions When machine fails,failure status will be self diagnosed to continue to run or stop,and send remote communication alarm.
Seismic design Using a special structure design, passing vibration testing to garuantee the reliability of its performance
Dual automatic switching function Automatically switch on standby unit after master unit keeps working for the set time. The standby unit continues the master unit's operating mode and speed to maintain the set temperature before switching status(sent from the master),and so forth, master and standby unit work in redundant.
Super air flow volume, no condensation Pathfinder CRAC has stronger air flow than normal ac units,with 15meters long and 160centigrade degrees wide air flow delivery,to garuantee to bring away the heat generated and end the condensation problem in computer room.
High quality control components Strict compliance with CE and IEC standards, advanced electronic control technology that can work reliably under 380V ± 30% power supply. |
Application Range
![]() |
|
Technical Parameters
Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
Power Supply | 380V 3Ph-50HZ | |||||||||||||
Air Discharge | Upflow/Downflow | |||||||||||||
Cooling Capacity :24℃/50%RH | ||||||||||||||
Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
Compressor Hermetic scroll | ||||||||||||||
Refrigerant | R407C | |||||||||||||
Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 |
Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 |
Material | PTC | |||||||||||||
Humidifier Section Electrode type | ||||||||||||||
Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 |
Packing & Delivery
Case