Specifications
Brand Name :
COOLNET
Model Number :
CYA,M08,CR012
Certification :
CE,ISO
Place of Origin :
CHINA
MOQ :
1set
Price :
USD1800-30000/set
Payment Terms :
T/T, L/C
Supply Ability :
300 PCS PER MONTG
Delivery Time :
20-40 days
Packaging Details :
Packed in plywooden case, standard export package
After-sales service provided :
Engineers available to service machinery overseas
Operating voltage :
380/400 VAC,230 VAC,220V
Fan type :
Axial Fan,Direct driven or belt driven,direct driven/belt driven/AC/EC plug fan,AC direct drive fan
Power :
3N-380V-50Hz,220v/50hz/60hz
Airflow :
2000~50000 m3/h
Voltage :
380v/220v,220V/380V,380V/415V
Description

Green And Energy Efficient Operation With Modular Data Center Space Saving

Product Introduction

Coolnet modular standardized data centers are designed with a standardized, modular architecture, meaning that infrastructure investments do not need to be made in one step when building the physical infrastructure of the data center, saving initial investment costs. Avoiding one-time investment in infrastructure such as cooling, power supply and racks takes up a lot of money and can result in idle resources. Instead, the data center of the required scale can be deployed only according to the current business needs, and then expanded as the business needs develop, and cooling, power supply, racks and other equipment can be invested in phases, greatly reducing the initial construction costs.

Benefits

Energy Efficient Operation Modular Data Center Space Saving

Energy Efficient Operation Modular Data Center Space Saving

Energy Efficient Operation Modular Data Center Space Saving

Features

Energy Efficient Operation Modular Data Center Space Saving

1. Customized hardware facilities to improve cost performance.

Modularized network architecture, customized servers, micro-modules and their infrastructure according to specific business deployment.

2,Factory prefabrication, on-site assembly, and rapid deployment.

Standardization and productization of components, high quality control and clear engineering interface.

3,Change the cooling method.

In row cooling to meet the requirements of medium and high power density server rooms (5-12kW/rack).

Proximity cooling, channel closure. Energy transfer in close proximity, cold and heat isolation, total energy consumption of the server room is reduced by 10%.

Can be based on IT cabinet requirements, server room area and power density and other factors, the flexibility of a variety of unit components organically assembled together to achieve a standard, balanced micro-module composition design, and can be customized according to the specific project situation, very flexible.

4,Cold pool and inter-row cooling

Composed of two columns of equipment units facing each other, plus the channel closure components, skylights, side doors, etc. itself to achieve cold and hot channel isolation.

The inter-column air supply distance is short, the refrigeration system control strategy is highly accurate, and it can also achieve flexible cooling on demand, while this approach supports high-density loads.

5,Comes with uninterruptible power supply system

Internal integrated UPS or 240V DC and battery uninterruptible power supply system. Different micro-modules can be powered by different power supply systems to achieve a variety of power supply forms mixed in the same room.

6,Easy disassembly and assembly

Prefabricated by the factory, with industrial and standardized features, can be easily disassembled and assembled. The construction time is short and the construction site is easy to manage.

Air Supply Method

Energy Efficient Operation Modular Data Center Space Saving

Technical Specification

Equipment System Item Parameter
System Dimension 1200mm enclosed cold/hot aisle dual-row cabinets
1200mm enclosed cold/hot aisle Single-row cabinets
Rack Quantity Dual Row Racks:≤48,Single Row Racks:≤24
Rack Dimensions 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U
Protection Class IP20
Enclosed Aisle Skylight 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight
Power Supply and Distribution Dimension 600mm(W)*1200mm(D)*2000mm(H)
UPS Power Supply 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99
Battery 40AH~240AH/12V Valve Regulated Lead Acid Battery
Cooling Indoor Unit Size 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H)
Cooling Capacity Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW
Power Supply 3Phase 380VAC,50Hz
Air Supply Front Supply
Type Enclosed Hot/Cold Aisle
Protection IP20
Monitoring System Monitoring Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm
Equipment monitoring Power supply, battery, power distribution, air conditioning

Factory Details

Energy Efficient Operation Modular Data Center Space Saving

Cases

Energy Efficient Operation Modular Data Center Space Saving

Send your message to this supplier
Send Now

Energy Efficient Operation Modular Data Center Space Saving

Ask Latest Price
Brand Name :
COOLNET
Model Number :
CYA,M08,CR012
Certification :
CE,ISO
Place of Origin :
CHINA
MOQ :
1set
Price :
USD1800-30000/set
Contact Supplier
Energy Efficient Operation Modular Data Center Space Saving
Energy Efficient Operation Modular Data Center Space Saving
Energy Efficient Operation Modular Data Center Space Saving

Hefei Coolnet power Co., ltd

Verified Supplier
5 Years
anhui, hefei
Since 2010
Business Type :
Manufacturer
Total Annual :
10,000,000.00-10,000,000.00
Employee Number :
100~150
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement