Specifications
Brand Name :
Coolent
Model Number :
CYAT40D/U
Certification :
ISO/CE
Place of Origin :
China
MOQ :
1
Price :
to be Negotiated
Payment Terms :
T/T
Supply Ability :
1000/Month
Delivery Time :
4W
Packaging Details :
WOODEN
cooling capacity :
45KW
Mounting :
Floor Standing
Type :
precision air conditioning unit( air cooled )
Operating voltage :
380/400 VAC,230 VAC,220V
Warranty :
1 Year
Product name :
CRAC Air Cooled Type Computer Room Cooling
Refrigerant :
R22(R407C/R410A)
Application :
Computer Room,Printing factory/cinema/supper marekt/restaurant/Offfice/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity
Color :
Black/Grey white/other custom colors
Power :
3N-380V-50Hz,220v/50hz/60hz
Airflow :
Upflow
Description

Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner

Products Introduction

Coolnet, with more than 30 years’ R&D and manufacturing experience in server room equipment field, depending on world-class labs, inspection and production equipment, not only can provide specialized products to meet the exact requirement of user’s job site, but also provide a perfect total solution for server room. Now our product range include precision air conditioner, UPS and data center solution.

CyberMasterTM Series Precision Cooling Unit: With high AEER system design and team work function, CyberMasterTM meets the cooling demand and reduce the PUE of the data center.

Benefits

Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner

Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner

Applications

Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner

„ Computer room and data center

„ Switch room and mobile center station in telecommunication

„ High-tech environment and lab

„ Industrial automation control room and precision manufacturing workshop

„ Standard test room and calibration center

„ UPS and battery room

„ Test room in hospital

„ Biochemical culture chamber

Features

1. High quality control component.

2. Efficient evaporator made from advanced technology and with larger heat exchange area.

3. Danfoss brand quality expansion valve.

4. Internationally advanced electrode steam humidification system.

5. Unique frame design guarantees the cabinet safety under any transport condition and operating environment.

6. G4 level air filter to guarantee the server room air purity.

7. Copeland hermetic scroll compressor.

8. Standard configuration with speed adjustable centrifugal fan. EC fan is optional.

9. Highly efficient PTC electrical heater.

10. Anti-corrosion alloy condenser.

Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner

Technical Parameters

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model 2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

Certificates

Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner

Factory Details

Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner

Packing & Delivery

Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner

Case

Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner

Send your message to this supplier
Send Now

Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner

Ask Latest Price
Brand Name :
Coolent
Model Number :
CYAT40D/U
Certification :
ISO/CE
Place of Origin :
China
MOQ :
1
Price :
to be Negotiated
Contact Supplier
Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner
Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner
Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner
Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner
Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner
Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner