Cold Aisle Containment Prefabricated Modular Data Center Air Cooling System 48u Cabinet
Product Introduction With the advent of the era of big data, the construction of information resources has been put on the agenda by more and more enterprises and institutions. As a carrier of massive data, data centers still face many problems such as high energy consumption, high costs, and low resource utilization. In the construction of a new generation of data centers, reducing the PUE value has become a key goal, and high heat density and local hot spots have also become key issues. Modular data centers and container micro-module data centers have become the design trend of the new generation of data centers.
Advantages
- Modular Design & Fast Deployment | ![]() |
Features
![]() | Flexible Reliable Standardized Solution (Modular Design &Fast Deployment) Two cabinets and roof ceiling form a unit of self-contained closed space/aisle.it is called hot or cold aisle containment, can be installed seneratedly.provide scalable solutions as demand change or erow. Modular desion nrovides scalable solutions to add cooling as demand increases. Intelligent Fire Safe System Alerts personnel and drops ceiling panels based on temperature to enable fire suppressions system in the room to extinguish the fire.Once fire signal alarm in roomthe top plate will open automatically and fire extinguishing gases can enter the aisle. Efficiency &Flexibility Increases the capacity of the air conditioner by supplying a warmer return air temperature. It supports for varying aisle widths, rack heights, rack depths, and single rows. Supports hot and cold aisle containment. Automatical Door Structure One-way locking door or safe slide doors secures the hot aisle while allowing for quick exit in case of emergency, the sliding door can be closed automaticallvcan be installed door access svstem and can be onened from inside to outside if an emergency occurs. Customization Providing customized solutions for your special requirements can be rapid deployment in your projects. |
Air Supply Method
Technical Specification
Equipment System | Item | Parameter |
System | Dimension | 1200mm enclosed cold/hot aisle dual-row cabinets |
1200mm enclosed cold/hot aisle Single-row cabinets | ||
Rack Quantity | Dual Row Racks:≤48,Single Row Racks:≤24 | |
Rack | Dimensions | 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U |
Protection Class | IP20 | |
Enclosed Aisle | Skylight | 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight |
Power Supply and Distribution | Dimension | 600mm(W)*1200mm(D)*2000mm(H) |
UPS Power Supply | 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99 | |
Battery | 40AH~240AH/12V Valve Regulated Lead Acid Battery | |
Cooling | Indoor Unit Size | 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H) |
Cooling Capacity | Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW | |
Power Supply | 3Phase 380VAC,50Hz | |
Air Supply | Front Supply | |
Type | Enclosed Hot/Cold Aisle | |
Protection | IP20 | |
Monitoring System | Monitoring | Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm |
Equipment monitoring | Power supply, battery, power distribution, air conditioning |