Server Room Large Exchange Rooms Dedicated In-Row Precise Air Cooling Systems
Product Introduction
Coolnet DX series in-row air conditioners are air conditioners developed for the cooling of server racks in small, medium and large communication data centers. It is especially suitable for micro-module systems with closed hot and cold aisles. The Coolnet DX series features a row-oriented cooling architecture, with each CRAC unit dedicated to cooling a row of server racks. CRAC units can be installed between racks, overhead, or under the floor. Airflow paths are shorter and more clearly defined than room-based cooling. This reduces the required CRAC fan power, increasing efficiency. The row-oriented design also allows cooling capacity and redundancy to be tailored to the actual needs of a particular row, maximizing smooth server operation.
Feature and Benefits | ![]() |
Application
| ![]() |
Structure & Componenets
![]() | EVO intelligent control system Control the air volume and cooling output as required, and cooperate with EC fan, electronic expansion valve and DC inverter compressor to achieve the best effect and lowest energy consumption; Adjust the speed of the internal fan according to the refrigeration demand, which can effectively reduce the noise; Group control function, realize up to 32 sets of group operation, including automatic main-standby switching, automatic operation of backup units, round robin, competition avoidance operation, temperature and humidity sensor sharing, etc.;
DC Inverter Compressor of DX System Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability
Backward Centrifugal EC Fan Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%; Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand; Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation; Soft start function, low starting current; Easy maintenance design |
Technical Parameter
Model | CRA013A | CRA020A | CRA040A | CRA050A | CRA060A |
Air supply | Front/Side | Front/Side | Front | Front | Front |
Power supply | 380VAC/3Ph/50Hz | ||||
Cooling capacity-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Sensible cooling-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Compressor | |||||
Refrigerant | R410A | ||||
Quantity | 1 | ||||
Fan | |||||
Fan type | EC Centrifugal fan | ||||
Quantity | 4 | 5 | 2 | 3 | 3 |
Air volume-m3/h | 3200 | 5000 | 8800 | 11000 | 12500 |
Heater | |||||
Heat type | PTC | ||||
Capacity-KW | 2 | 3 | 6 | 6 | 6 |
Humidification | |||||
Capacity-KW | 1 | 1.5 | 3 | 3 | 3 |
Certificates
Factory Details
Packing & Delivery
|
Cases
|