Specifications
Brand Name :
Coolent
Model Number :
XR040
Certification :
ISO/CE
Place of Origin :
China
MOQ :
1
Price :
to be Negotiated
Payment Terms :
T/T
Supply Ability :
1000/Month
Delivery Time :
4W
Packaging Details :
WOODEN
cooling capacity :
40KW
Mounting :
Floor Standing
Condition :
New
Type :
In Row Air conditioning
After-sales service provided :
Engineers available to service machinery overseas
Power Supply :
380/400 VAC,230 VAC,220V , 50/60HZ
Warranty :
1 Year
Product name :
Row Based Cooling Unit
Refrigerant :
R410A
Application :
Modularized data center, High heat density data center, Container data center
Description

In Row Air Conditioning Row Based Cooling Unit For High Heat Density Data Center

Product Introduction

Cool Row series In Row air conditioning increase the heat density of the data center and realize the energy saving of the data center. Compared with traditional computer room air conditioners, In Row air conditioning have the characteristics of 100% sensible heat ratio, low fan power consumption, high energy efficiency ratio, low computer room decoration requirements, convenient installation, standardized cabinet design and easy expansion.

Features & Advantages

  • It achieves a 100% high sensible heat ratio, which effectively reduces the overall humidification and dehumidification energy consumption of the computer room.
  • Control the air volume and cooling output as required, and cooperate with EC fan, electronic expansion valve and DC inverter compressor to achieve the best effect and lowest energy consumption;
  • Adjust the speed of the internal fan according to the refrigeration demand, which can effectively reduce the noise;
  • Group control function, realize up to 32 sets of group operation, including automatic main-standby switching, automatic operation of backup units, round robin, competition avoidance operation, temperature and humidity sensor sharing, etc.;
In Row Air Conditioning Cooling Unit For High Heat Density Data Center
In Row Air Conditioning Cooling Unit For High Heat Density Data Center

Applicable Scene

■Local overheating area

■ High heat density data center

■ Modularized data center

■ Container data center

■ Data centers with insufficient floor heights that cannot use down-supply air or pipelines

■The cabinet adopts cold and hot aisle layout

High Efficiency-DC Inverter Compressor of DX System

Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability

High Efficiency-Backward Centrifugal EC Fan

Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;

Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;

Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;

Soft start function, low starting current; Easy maintenance design

High Efficiency-Electronic Expansion Valve

Smoothly adjust the throttle opening, matched with variable capacity compressor To achieve energy saving;

Wide adjustment range, reduce superheat and improve energy efficiency ratio Reduce cooling capacity and load;

Fast response speed, realizing precise refrigeration;

Structure & Components

In Row Air Conditioning Cooling Unit For High Heat Density Data Center

Technical Parameter

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

Certificates

In Row Air Conditioning Cooling Unit For High Heat Density Data Center

Factory Details

In Row Air Conditioning Cooling Unit For High Heat Density Data Center

Packing & Delivery

In Row Air Conditioning Cooling Unit For High Heat Density Data Center

Cases

In Row Air Conditioning Cooling Unit For High Heat Density Data Center

Send your message to this supplier
Send Now

In Row Air Conditioning Cooling Unit For High Heat Density Data Center

Ask Latest Price
Brand Name :
Coolent
Model Number :
XR040
Certification :
ISO/CE
Place of Origin :
China
MOQ :
1
Price :
to be Negotiated
Contact Supplier
In Row Air Conditioning Cooling Unit For High Heat Density Data Center
In Row Air Conditioning Cooling Unit For High Heat Density Data Center
In Row Air Conditioning Cooling Unit For High Heat Density Data Center

Hefei Coolnet power Co., ltd

Verified Supplier
5 Years
anhui, hefei
Since 2010
Business Type :
Manufacturer
Total Annual :
10,000,000.00-10,000,000.00
Employee Number :
100~150
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement