Specifications
Brand Name :
Coolnet
Model Number :
DX 546-740
Certification :
CE/ISO9001
Place of Origin :
China
MOQ :
1
Payment Terms :
T/T
Delivery Time :
4W
Packaging Details :
WOODED
Cooling capacity :
45-50kw
Product Condition :
New
Mounting :
Floor Standing Mount
Type of Product :
Precision air conditioning unit(chilled water) 3ton 5ton 10ton
After-sales Service :
Engineers available to service machinery overseas
Voltage :
380/400 VAC,230 VAC,220V
Warranty :
1 Year(12 month)
Product name :
Precision Air Conditioning
Precision Air Conditioning :
R22(R407C/R410A)
Application :
Computer Room/Printing factory/cinema/supper marekt/restaurant/Offfice/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity
Color :
Black/Grey/White/other custom colors
Type of Fan :
Axial Fan,Direct driven or belt driven,direct driven/belt driven/AC/EC plug fan,AC direct drive fan
Power :
3N-380V-50Hz,220v/50hz/60hz
Airflow :
8000~50000 m3/h
Description

Low Energy Demand 10000m3/H Airflow Air Cooling For Program-Controlled Switch Rooms

Product Introduction

Precision air conditioners are widely used in high-precision environments such as computer rooms, program-controlled switch rooms, satellite mobile communication stations, large medical equipment rooms, laboratories, testing rooms, and precision electronic instrument production workshops. Various indicators such as cleanliness and airflow distribution have high requirements. The computer room air conditioner operates 24 hours a day, 365 days a year. It can ensure the normal refrigeration cycle of the computer room through the controllable outdoor condenser, thereby ensuring the normal operation of the equipment in the computer room.

Benefits

10000m3/H Precision Air Conditioning Units For Program Controlled Switch Rooms

10000m3/H Precision Air Conditioning Units For Program Controlled Switch Rooms

Technical Features

10000m3/H Precision Air Conditioning Units For Program Controlled Switch Rooms

1. High quality control component.

2. Efficient evaporator made from advanced technology and with larger heat exchange area.

3. Danfoss brand quality expansion valve.

4. Internationally advanced electrode steam humidification system.

5. Unique frame design guarantees the cabinet safety under any transport condition and operating environment.

6. G4 level air filter to guarantee the server room air purity.

7. Copeland hermetic scroll compressor.

8. Standard configuration with speed adjustable centrifugal fan. EC fan is optional.

9. Highly efficient PTC electrical heater.

10. Anti-corrosion alloy condenser.

Applications

  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber
10000m3/H Precision Air Conditioning Units For Program Controlled Switch Rooms

Advantages

10000m3/H Precision Air Conditioning Units For Program Controlled Switch Rooms

Precise and reliable
Careful design, strict laboratory testing and comprehensive quality control ensure the unit has excellent reliability;The unit uses parts of world-renowned brands to ensure the high reliability and service life of the whole machine.
Energy saving and high efficiency

Energy saving and high efficiency
Save a lot of energy consumption in a reasonable and feasible way, and make full use of natural resources;
The unit uses a high-efficiency fan and a fully enclosed compressor system to reduce operating costs and always pay attention to energy efficiency.

Multiple air supply
The air supply method of the air-conditioned room depends on the source and distribution characteristics of the heat in the room. According to the dense arrangement of equipment in the computer room, the number of cables and bridges, and the wiring method, the air supply method of the air conditioner is divided into lower delivery, upper return, top feed back, top feed side back, side feed side back.

Static pressure box air supply
The air conditioner in the computer room usually does not use pipes, but uses the space at the lower part of the raised floor or the upper part of the ceiling as the return air of the static pressure box. static pressure is equal.

Technical Parameters

Model: CYA S20D/U S23D/U S26D/U S28D/U S31D/U S35D/U S40D/U S45D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity KW 20.5 23.5 26.8 28.3 31.5 35.5 40.2 45.6
Sensible KW 18.9 21.6 24.2 26.1 28.9 33.2 37.6 42.2
AEER w/w 3.7 3.6 3.6 3.7 3.7 3.7 3.7 3.6
Air Flow m3/h 6830 7650 7580 8500 9200 9800 10600 12000
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 1 1 1 1 1 1 1 1
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 1 1 1 1 1 1 2 2
Rated current A 2.5 2.5 2.8 3.2 3.5 4.1 4.4 4.9
Rated power W 1050 1100 1200 1300 1320 2000 2150 2400
Reheat Capacity KW 6 6 6 6 9 9 9 9
Reheat Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 5 5 5 13
Rated Current A 6 6 6 6 6 6 6 15
Condensor Model 58 58 80 80 100 120 150 150

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model 2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

Certificates

10000m3/H Precision Air Conditioning Units For Program Controlled Switch Rooms

Factory Details

10000m3/H Precision Air Conditioning Units For Program Controlled Switch Rooms

Packing & Delivery

10000m3/H Precision Air Conditioning Units For Program Controlled Switch Rooms

Case

10000m3/H Precision Air Conditioning Units For Program Controlled Switch Rooms

Send your message to this supplier
Send Now

10000m3/H Precision Air Conditioning Units For Program Controlled Switch Rooms

Ask Latest Price
Brand Name :
Coolnet
Model Number :
DX 546-740
Certification :
CE/ISO9001
Place of Origin :
China
MOQ :
1
Payment Terms :
T/T
Contact Supplier
10000m3/H Precision Air Conditioning Units For Program Controlled Switch Rooms
10000m3/H Precision Air Conditioning Units For Program Controlled Switch Rooms
10000m3/H Precision Air Conditioning Units For Program Controlled Switch Rooms
10000m3/H Precision Air Conditioning Units For Program Controlled Switch Rooms

Hefei Coolnet power Co., ltd

Verified Supplier
5 Years
anhui, hefei
Since 2010
Business Type :
Manufacturer
Total Annual :
10,000,000.00-10,000,000.00
Employee Number :
100~150
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement