Specifications
Brand Name :
Coolent
Model Number :
DX755-7120
Certification :
ISO/CE
Place of Origin :
China
MOQ :
1
Price :
to be Negotiated
Payment Terms :
T/T
Supply Ability :
1000/Month
Delivery Time :
4W
Packaging Details :
WOODEN
Capacity :
60-75KW
Mounting :
Floor Standing
Color :
Black/Grey/White/Other Custom Colors
Product Name :
Precision Air Conditioners For Small Medium And Large IT Data Center And Medical Labs
Refrigerant :
R22(R407C/R410A)
Application :
Computer Rooms/Data Centers/Medical Equipment Room/Satellite Exchange Stations
Airflow :
9800m3/h
Condition :
New
Voltage :
380V
Description

Large And Precise Medical Equipment Rooms 100kw Cooling Capacity PAC Units

Product Introduction

Coolnet power is specialiaed in PAC, UPS and other products or equipments in data centers and telecommunication industry. Coolnet precision air conditioners are widely surved for high-precision environments such as computer rooms, program-controlled switch rooms, satellite mobile communication stations, large medical equipment rooms, laboratories, testing rooms, and precision electronic instrument production workshops. Various indicators such as cleanliness and airflow distribution have high requirements.

Feature and Benefits

100kw Cooling Capacity PAC Units For Large Precise Medical Equipment Rooms

100kw Cooling Capacity PAC Units For Large Precise Medical Equipment Rooms

Main Accessories

100kw Cooling Capacity PAC Units For Large Precise Medical Equipment Rooms

Fan:

Use the efficient and low-noise EBM backward tilt centrifugal wind motorized balance test to ensure long life, high energy efficiency, low energy consumption and low noise operation. Compared with equipment with the same air volume in the industry, the power consumption is the lowest.

Condenser:

The air-cooled condenser is made of marine grade corrosion-resistant materials, has outstanding rigidity and anti-corrosion functions, and is accustomed to various environmental conditions. Fully adjustable speed electric fans are used to achieve energy saving and low noise.

Compressor:

Use a scroll compressor with a high energy efficiency ratio. The reduction of the moving parts of the scroll compressor reduces the noise and sensation of the unit a lot; the compression process of the compressor is continuous and stable; the rotation viewpoint of the exhaust process of the compressor exceeds 540 degrees; there is no heat exchange during the inhalation and compression process; In the process of compaction, the direction of refrigerant airflow is not changed; the airflow loss is reduced; the scroll compressor does not need high and low pressure valves; the volume loss of the valve is reduced, and the patented dynamic and static scroll separation technology can effectively avoid liquid shock; launch The current is low. The energy efficiency ratio of similar compressors is the highest, reaching 3.4.

Expansion Valve:

Smoothly adjust the throttle opening and cooperate with the variable capacity compressor to achieve energy saving;Wide adjustment range, reduce superheat and improve energy efficiency ratio;Reduce cooling capacity and load;Fast response speed, realizing precise refrigeration
Dual electronic expansion valve design, low load dehumidification

Humidifier:

Direct electrode humidifier;W-type electrode combination suitable for poor water quality;Fuzzy logic control humidification program
Removable for cleaning;Microcomputer-controlled automatic flushing cycle process;Low noise water supply solenoid valve to ensure quietness

Air Supply Method

100kw Cooling Capacity PAC Units For Large Precise Medical Equipment Rooms

Advantages

  • High reliability, high energy saving rate, high adaptability, low cost throughout life
  • The air-conditioning unit adopts a modular design, the compressor and evaporator of a refrigeration system are in the same module, and the transportation and handling module is disassembled
  • No need to cut and weld copper pipe100% full frontal maintenance, saving space in the computer room
  • Mitsubishi/Hitachi inverter high-efficiency compressor
  • Multiple energy-saving designs and energy-saving integrated designs, including iFreecooling fluorine pump double circulation
  • A variety of air supply methods (upper duct air supply, upper hood air supply, fan down-type air supply) to meet the needs of different airflow organizations
  • A variety of cooling methods, including air cooling, water cooling, etc., are conducive to adapting to the actual conditions of the site
  • Standard RS485 communication interface, ModBus communication protocol
  • Multiple monitoring methods
  • Air-cooled condensers are available in configurations suitable for different temperature environments, including low temperature start-up
  • The air-cooling method provides a solution with ultra-long installation distance and ultra-high drop
  • Large humidification capacity, suitable for poor water quality, low maintenance
  • Frequency conversion series units are equipped with oil separator as standard
  • The power consumption per 1kg/h of humidification should not exceed 0.8kW to achieve energy-saving operation.
100kw Cooling Capacity PAC Units For Large Precise Medical Equipment Rooms

Technical Parameters

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model 2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

Certificates

100kw Cooling Capacity PAC Units For Large Precise Medical Equipment Rooms

Factory Details

100kw Cooling Capacity PAC Units For Large Precise Medical Equipment Rooms

Packing & Delivery

100kw Cooling Capacity PAC Units For Large Precise Medical Equipment Rooms

Case

100kw Cooling Capacity PAC Units For Large Precise Medical Equipment Rooms

Send your message to this supplier
Send Now

100kw Cooling Capacity PAC Units For Large Precise Medical Equipment Rooms

Ask Latest Price
Brand Name :
Coolent
Model Number :
DX755-7120
Certification :
ISO/CE
Place of Origin :
China
MOQ :
1
Price :
to be Negotiated
Contact Supplier
100kw Cooling Capacity PAC Units For Large Precise Medical Equipment Rooms
100kw Cooling Capacity PAC Units For Large Precise Medical Equipment Rooms
100kw Cooling Capacity PAC Units For Large Precise Medical Equipment Rooms
100kw Cooling Capacity PAC Units For Large Precise Medical Equipment Rooms

Hefei Coolnet power Co., ltd

Verified Supplier
5 Years
anhui, hefei
Since 2010
Business Type :
Manufacturer
Total Annual :
10,000,000.00-10,000,000.00
Employee Number :
100~150
Certification Level :
Verified Supplier
Contact Supplier