High Availability Micro Data Centers Applied For Small Companies In Telecommunications
Product Introduction
Coolnetpower Micro Data Center integrates the data center infrastructure products, including UPS, power distribution, refrigeration, cabinets, fire protection and other subsystems, and realizes overall management of all systems through the monitoring system, simplifying the design and construction process.The reliable UPS power distribution system continuously escorts the IT equipment. At the same time, it is equipped with a precision refrigeration system to ensure the operating environment of the IT equipment, and it is matched with the dynamic environment monitoring system to monitor the working status of the equipment in real time. The integrated cabinet adopts a fully sealed design and can be used in a variety of harsh indoor environments without the need for a separate computer room. | ![]() |
Advantages
![]() | Simpler Integrated design, integrate UPS, battery, power distribution, air conditioning, monitoring, wiring, fire protection and other products in the cabinet, get rid of the traditional sub-construction mode; modular design, unified interface of each component.
Faster Carrying out the product design of the traditional project, saving the time of preliminary project design and on-site installation, and completing all the installation projects within one day, which is more than 2 times faster than the traditional construction mode.
More secure Perform in-depth integration of various systems and factory pre-verification tests, which are more standardized, safer and more reliable than free construction on site; provide different reliability levels of architecture schemes for selection (N, N+1, 2N).
Lower cost The minimum area of the equipment is only 0.7m2, which reduces the demand for the area of the computer room, does not require decoration, flooring and other supporting projects, and reduces the cost of infrastructure construction; high-efficiency UPS system, frequency conversion precision air conditioner + fully enclosed heating and cooling.
Better management One-stop after-sales service can handle all kinds of equipment failure problems in time, saving time and worry; standard dynamic loop monitoring system, providing various reports and data statistics, local and remote monitoring and management, and multi-site access to the upper management platform Unified supervision, diversified choice support. |
Application
Suitable for small and medium-sized computer rooms; the central computer room of the convergence layer that requires monitoring and management, cabinet cascading, modular construction, and phased deployment. 1. Financial outlets, government, education, medical, military, transportation, small and medium-sized enterprises, supermarkets and retail, etc. 2. No special small computer room is required (less than 50 square meters, or the width is not enough for the computer room) 3. Mainly for load: a small number of core equipment such as servers, switches, gateways and firewalls. 4. Main application areas: construction of small and micro computer rooms, transformation of simple computer rooms, computer rooms of various branches, public security law, universities, hospitals, enterprises, hospitals, city and county business centers (finance, three major operators, etc.). | ![]() |
Technical Parameter
Model | EC08 | EC12 | EC20 | ERx |
Power | 3KVA | 3-6KVA | 6-30KVA | |
Number of cabinets | 0.8m high cabinet, available space 8U | 1.2m high cabinet, available space 16U | Standard 42U cabinet, free space 30U | 2-10 standard 42U glass door cabinets |
Enclosed cabinet | Glass door, IP5X, full cold and hot channel sealing | |||
Power supply | 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection | 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection | 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection | |
Refrigeration | Unique air duct design, without air conditioner and outdoor unit | Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | |
Monitor | 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display | 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring | 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring |
Factory View
Case