Specifications
Brand Name :
COOLNET
Model Number :
MAC10-RS45810
Certification :
CE,ISO
Place of Origin :
CHINA
MOQ :
1set
Price :
1800-30000USD
Payment Terms :
T/T, L/C
Supply Ability :
300 PCS PER MONTG
Delivery Time :
10-25 working days
Packaging Details :
Packed in plywooden case, standard export package
Cooling capacity :
20-50KW (per rack)
Product Condition :
Brand New
Mounting :
Floor Standing
Type :
Modular data centers (19" Standard Server Cabinet)
After-sales service provided :
Engineers available to service machinery overseas
Operating voltage :
380/400 VAC,230 VAC,220V
Warranty :
1 Year(12 month with no artificial damage)
Name :
Modular Data Center
Refrigerant :
R22(R407C/R410A)
Application :
Data Center,Colocation Server Rack Room,Edge Computing, 5G, Smart City
Power :
3N-380V-50Hz,220v/50hz/60hz
Voltage :
380v/220v,220V/380V,380V/415V
Intelligent :
Yes
Modular Data Centers :
Yes
Description

Intelligent Efficient And Space-Saving Modular Data Center For Stability Of IT Devices

Product Introduction

Modular data centers are composed of multiple prefabricated, standardized modular units, which usually include computing, storage, power supply, cooling, and network infrastructure. Each module can be produced, transported, and quickly assembled on site into a complete data center. This "modular" design enables data centers to flexibly expand and shrink according to demand.

Benefits

Intelligent Cloud Computing Operation Management Platform For Modular Data Centers

Intelligent Cloud Computing Operation Management Platform For Modular Data Centers

Intelligent Cloud Computing Operation Management Platform For Modular Data Centers

Advantages

Intelligent Cloud Computing Operation Management Platform For Modular Data Centers

High density, intelligent advantage

The modular data center adopts the scheme of horizontal air supply near the row air conditioner and closed cold/hot aisles, reducing the range of air supply and return. The airflow does not interfere with each other. Each cabinet in the server can be considered as an independent cooling unit, which improves the cooling efficiency greatly. The in-row air conditioners deliver the cooling capacity directly to the server cabinet through point-to-point precise cooling, which ensures the support for the cooling capacity of the high-density data center and supports the power of a single cabinet.

Configure on demand

Modular data center mainly includes a series of power equipment with modular design, such as uninterruptible power supply, refrigeration system, rack and remote monitoring system, etc., through simple interfaces to combine related modules to form a complete data center center. Thus, companies and enterprises can customize a modular data center according to its own needs, and can gradually expand the scale of the data center to meet more IT needs along with business development needs.

Short construction period

The deployment time of the modular data center is shorter. It only takes more than ten weeks to complete the application from design to formal deployment, and it also saves space. On the one hand, it has integrated a large number of power infrastructure equipment, which can be put into operation only by adding corresponding IT equipment. On the other hand, the modular design is more conducive to site selection.

Operational cost reduction

Modular data centers help users reduce costs in the initial construction stage through modular and customized design, and control energy consumption through centralized management of IT facilities in the later operation stage; In addition, this construction method can also be used to help enterprises improve space and equipment utilization, reduce unnecessary human resource consumption, and effectively control their comprehensive operating cost.


Technical Specification

Equipment System Item Parameter
System Dimension 1200mm enclosed cold/hot aisle dual-row cabinets
1200mm enclosed cold/hot aisle Single-row cabinets
Rack Quantity Dual Row Racks:≤48,Single Row Racks:≤24
Rack Dimensions 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U
Protection Class IP20
Enclosed Aisle Skylight 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight
Power Supply and Distribution Dimension 600mm(W)*1200mm(D)*2000mm(H)
UPS Power Supply 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99
Battery 40AH~240AH/12V Valve Regulated Lead Acid Battery
Cooling Indoor Unit Size 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H)
Cooling Capacity Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW
Power Supply 3Phase 380VAC,50Hz
Air Supply Front Supply
Type Enclosed Hot/Cold Aisle
Protection IP20
Monitoring System Monitoring Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm
Equipment monitoring Power supply, battery, power distribution, air conditioning

Certificates

Intelligent Cloud Computing Operation Management Platform For Modular Data Centers

Factory Details

Intelligent Cloud Computing Operation Management Platform For Modular Data Centers

Parking & Delivery

Intelligent Cloud Computing Operation Management Platform For Modular Data Centers

Cases

Intelligent Cloud Computing Operation Management Platform For Modular Data Centers

Production Line and Warehouse​

Advantages

Send your message to this supplier
Send Now

Intelligent Cloud Computing Operation Management Platform For Modular Data Centers

Ask Latest Price
Watch Video
Brand Name :
COOLNET
Model Number :
MAC10-RS45810
Certification :
CE,ISO
Place of Origin :
CHINA
MOQ :
1set
Price :
1800-30000USD
Contact Supplier
video
Intelligent Cloud Computing Operation Management Platform For Modular Data Centers
Intelligent Cloud Computing Operation Management Platform For Modular Data Centers
Intelligent Cloud Computing Operation Management Platform For Modular Data Centers

Hefei Coolnet power Co., ltd

Verified Supplier
5 Years
anhui, hefei
Since 2010
Business Type :
Manufacturer
Total Annual :
10,000,000.00-10,000,000.00
Employee Number :
100~150
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement