Intelligent Efficient And Space-Saving Modular Data Center For Stability Of IT Devices
Product Introduction
Modular data centers are composed of multiple prefabricated, standardized modular units, which usually include computing, storage, power supply, cooling, and network infrastructure. Each module can be produced, transported, and quickly assembled on site into a complete data center. This "modular" design enables data centers to flexibly expand and shrink according to demand.
Benefits | ![]() |
Advantages
| High density, intelligent advantage The modular data center adopts the scheme of horizontal air supply near the row air conditioner and closed cold/hot aisles, reducing the range of air supply and return. The airflow does not interfere with each other. Each cabinet in the server can be considered as an independent cooling unit, which improves the cooling efficiency greatly. The in-row air conditioners deliver the cooling capacity directly to the server cabinet through point-to-point precise cooling, which ensures the support for the cooling capacity of the high-density data center and supports the power of a single cabinet. Configure on demand Modular data center mainly includes a series of power equipment with modular design, such as uninterruptible power supply, refrigeration system, rack and remote monitoring system, etc., through simple interfaces to combine related modules to form a complete data center center. Thus, companies and enterprises can customize a modular data center according to its own needs, and can gradually expand the scale of the data center to meet more IT needs along with business development needs. Short construction period The deployment time of the modular data center is shorter. It only takes more than ten weeks to complete the application from design to formal deployment, and it also saves space. On the one hand, it has integrated a large number of power infrastructure equipment, which can be put into operation only by adding corresponding IT equipment. On the other hand, the modular design is more conducive to site selection. Operational cost reduction Modular data centers help users reduce costs in the initial construction stage through modular and customized design, and control energy consumption through centralized management of IT facilities in the later operation stage; In addition, this construction method can also be used to help enterprises improve space and equipment utilization, reduce unnecessary human resource consumption, and effectively control their comprehensive operating cost. |
Technical Specification
Equipment System | Item | Parameter |
System | Dimension | 1200mm enclosed cold/hot aisle dual-row cabinets |
1200mm enclosed cold/hot aisle Single-row cabinets | ||
Rack Quantity | Dual Row Racks:≤48,Single Row Racks:≤24 | |
Rack | Dimensions | 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U |
Protection Class | IP20 | |
Enclosed Aisle | Skylight | 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight |
Power Supply and Distribution | Dimension | 600mm(W)*1200mm(D)*2000mm(H) |
UPS Power Supply | 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99 | |
Battery | 40AH~240AH/12V Valve Regulated Lead Acid Battery | |
Cooling | Indoor Unit Size | 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H) |
Cooling Capacity | Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW | |
Power Supply | 3Phase 380VAC,50Hz | |
Air Supply | Front Supply | |
Type | Enclosed Hot/Cold Aisle | |
Protection | IP20 | |
Monitoring System | Monitoring | Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm |
Equipment monitoring | Power supply, battery, power distribution, air conditioning |