Corrosion Resistant Lightweight Steel Truss Structure For Prefab House
1, main used for aluminum project
2, tube size:6061-T1,6068-T2
3, we receive related aluminum roof engineering projects
4, we designed the roof alumium truss is solid
5, we welcome receive all of the engineering projectpcifict
Size(mm) | Main Tube(mm) | Horizontal tube(mm) | Brace Tube(mm) | Loading Capacity(kg) | Span(m) |
300*300 | 50*3 | 25*2 | 20*2 | 440 | 12 |
350*350 | 50*3 | 25*2 | 20*2 | 450 | 15 |
400*400 | 50*3 | 25*2 | 25*2 | 470 | 16 |
450*450 | 50*3 | 30*2 | 25*2 | 500 | 17 |
500*500 | 50*3 | 50*2 | 25*2 | 600 | 20 |
520*760 | 50*3 | 50*2 | 25*2 | 1000 | 22 |
600*760 | 50*3 | 50*2 | 25*2 | 1500 | 26 |
FEATURE
portable modular roof truss system
fashion truss
long-span roof truss
CE ,SGS Material analysis
Material | Aluminum 6061/T6,6082/T6 |
Length available | 1m,2m,3m,4m |
Shape | Ladder,Triangle,Square,Circle Truss |
Color | Silvery and black or customized |
Type | Spigot and screw |
Certification | TUV,CE,SGS |
Characteristics | Durable,Light Weight with high loading capacity.Raw material is aprecipitation hardening aluminum alloy, Containing magnesium and silicon as its major alloying elements. It has good mechanical properites, exhibits good weldability. It also has good effect of Proof Stress, corrosion resistance, antioxidation. |
application | Apply to give class square building, aluminum alloy construction |
Detailed Project Information |
Specification | Structure type | Space frame |
Design standard | AISI/ASTM/BS/DIN/GB/JIS | |
Length | With customer's requirement | |
Width | Single span,double-span,multi-span | |
Height | With customer's requirement | |
Components | Bolt ball: | Steel grade 45 |
Column | Q235B, Q345B welded H section steel | |
Beam | Q235B, Q345B welded H section steel | |
Tube: | Steel Q235B, Q345B | |
High strength bolt: | Cr 40, 10.9S, 9.8S, galvanization | |
Sleeve: | Steel Q235B, Q345B & 45, galvanization | |
Purlin: | Q235B C channel or Z channel, galvanization | |
Roof & Wall panel: | Sandwich panels,Corrugated steel sheet,FRP sheet |
Design Parameter We Need:
If you need us to provide an accurate design and quotation for you,
please send us the following design data.
1. TECH. INFO.
* Roof dead load/ Roof live load
* Floor dead load/ Floor live load
* Snow load
* Basic wind load or wind speed
* Servise load: Ceiling load / Air conditioning, ventiduct / Fire, spray / Lighting, audio facilities
* Cat walk: Selfweight / Service load
*Seismic acceleration
*Other load
2. Needed drawings
* Structure Layout plan/Section/Elevation drawing
* The client offered drawings should clearly state the dimension.
* The client offered drwaings should clearly state the support location and elevation.
* If you have no drawings,we will design as our experience for you to confirm.