With reputation of quality and innovation, the CA368-M is built up on the basis of classic CA368 three phase foure wire electric meter with extended functionalities for diversity of metrological element measurement and high-end automated smart metering. It is a tamper-proof reinforced multi-rate mete finished in a British Standard 5685 footprint housing, mainly intended for commercial and inustrial environments. The meter type is exclusively designed to optimize the buisness renvenue collection process and ideal for service providers and utilities to manage their tenants power usage and entire grid health.
The CA368-M supports unidirectional measurement for active and reactive energy and offers up to four tariffs and 108 holiday settings. The meter operates in four-wire pattern in one, two or three phase configurations as well as three-wire partterns. The meter is manfuactured by IEC 62053, EN 50670 (MID) in its mechanical spec , and ISO9001 standards with rugged RF immunity withstand of 30Vm, allowing it to be installed in very harsh environmens.
The CA368-M operates with wireless communication such as PLC, RF, M-bus, GPRS/ GSM, 4G Lte according to local infrastructure, allowing it to be connected with a back-end central server for AMR AMI smart metering applications. This feature offers utility and service provider free choice of communication with AMR / AMI setups.
Featured functions
■Programmable power limitation setting for load contol purpose
■ Multi-rate with Time of Use tariff allows for flexible contractual control
■Terminal block is available for both whole current and CT/VT connection
■LED consumption indicator
■4 programmed channels measurement
■Optical and RS485 com port
User benefits
1) Cost saving and improved efficiency by reducing inventory
2) Scalable setup allows for starting with low end and developing towards high end
3) Low operational and maintenance cost
4) Easy to install and deploy
5) Fraud detection and alarm for tamper detected
Specifications:
Electrical parameters | |
---|---|
Nominal voltage Un | 3x 220/230/ 240V |
Limited voltage | 60%~120%Un |
Frequency | 50/60Hz+5% |
Basic current(Ib) | 5A |
Maximum current(Imax) | 100A |
Starting current(Ist) | 30mA |
Active energy constant | 400imp/kWh |
Accuracy |
|
Active energy to IEC62053‐21 | Class1.0 |
Reactive energy to IEC62053‐23 | Class2.0 |
Power Consumption |
|
Power consumption in Voltage circuit | <2W <8VA |
Power consumption in current circuit | <1VA |
Temperature range |
|
Operation meter | 25℃ to+70℃ |
Storage | 40℃ to+85℃ |
| |
Insulation strength | |
AC Insulation strength | 4kV at 50Hz during 1min |
Impulse voltage 1.2/50μs mains connections | 8kV |
|
|
Electro Magnetic Compatibility | |
Electrostatic discharges |
|
Contact discharge | 8kV |
Air discharge | 16kV |
Electromagnetic RF fields |
|
27MHz to 500MHz typical | 10V/m |
100kHz to 1GHz typical | 30V/m |
Fast transient burst test | 4kV |
Mechanical requirements |
|
Protection Rating | IP54 |
Insulation Classification | Protective Class II |