Specifications
Brand Name :
MKIMM
Model Number :
MKIMM
Certification :
ISO
Place of Origin :
henan
MOQ :
1
Price :
bargain
Payment Terms :
T/T,L/C,Paypal,Alipay,West Union and so on
Supply Ability :
25 every month
Delivery Time :
15days
Packaging Details :
wooden box
After-sales Service Provided: :
Free spare parts, Video technical support, Field installation, commissioning and training, Field maintenance and repair service, Online support
Local Service Location: :
None
Surface Finish: :
0.28-0.4um
Product name: :
Customizable Stainless Steel Shell & Tube /Double Tube Heat Exchanger
Dimension(L*W*H): :
Customisation
Liquid Flow Rate: :
1-3m/s
Condition :
New
Warranty of core components: :
1 Year
Description

High Rate Double Tube Plate Fixed Type Spiral Wound Tube Heat Exchanger

Description

Double tube sheet heat exchanger is an energy-saving equipment that realizes heat exchange between materials, and it is widely used in various fields of the national economy. In order to prevent corrosion and pollution in production, and to meet the requirements of technological process, labor protection, safety production, etc., double tube sheet heat exchangers are usually used to solve the problem.

Parameter

Model

Capacity

KW

Water Flow

m3/h

External and Installation

dimensions

A B C D E F G H R L

Freon

Out

a1(Φ)

Freon
In

a2(Φ)

Water In/Out

a3

N.W

Kg

5*2EKG 23.2 4.0 1180 170 90 1020 350 600 60 200 40 40 22 19 50 42
8*2EKG 37.2 6.5 1180 200 100 1010 200 800 60 200 40 40 28 19 63 56
10*2EKG 46.5 8.0 1420 200 100 1250 370 800 60 200 40 40 28 19 63 65
12*2EKG 56.0 9.6 1460 225 100 1290 250 1000 60 200 43 43 28 22 63 78
15*2EKG 70.0 12.0 1360 250 100 1190 200 1000 60 260 53 53 28 22 63 96
20*2EKG 93.0 16.0 1720 250 110 1540 300 1200 60 260 53 53 38 28 75 115
25*2EKG 116 20.0 2120 250 110 1940 500 1200 60 260 53 53 38 28 75 136
30*2EKG 140 24.0 2030 280 110 1850 500 1200 60 260 65 65 38 28 75 160
35*2EKG 163 28.0 2340 280 120 2150 500 1500 60 260 65 65 38 28 90 182

application

The double tube sheet heat exchanger is a heat exchanger with two tube sheets with a certain gap at one end of the heat exchanger or equivalent to two tube sheets with a certain gap. In actual operation, double tube sheet heat exchangers are generally used in the following two occasions: one is to absolutely prevent the mixing of media between the shell and the shell, for example, for the shell-side water, the tube-side chlorine or chloride. In the heat exchanger, if the water in the shell side comes into contact with the chlorine or chloride in the tube side, highly corrosive hydrochloric acid or hypochlorous acid will be produced, which will cause severe corrosion to the tube side material.

The use of double tube sheet structure can effectively prevent the mixing of the two materials, thereby preventing the occurrence of the above accidents; the other is the occasion where the medium pressure difference between the tube and shell sides is large, which is usually in the cavity between the inner and outer tube sheets. Add a medium to reduce the pressure difference of the medium between the tube and shell sides.

Spiral Double Tube Sheet Heat Exchanger 4.0m3/H 8.0m3/H Tubular Condenser

Spiral Double Tube Sheet Heat Exchanger 4.0m3/H 8.0m3/H Tubular Condenser

Send your message to this supplier
Send Now

Spiral Double Tube Sheet Heat Exchanger 4.0m3/H 8.0m3/H Tubular Condenser

Ask Latest Price
Brand Name :
MKIMM
Model Number :
MKIMM
Certification :
ISO
Place of Origin :
henan
MOQ :
1
Price :
bargain
Contact Supplier
Spiral Double Tube Sheet Heat Exchanger 4.0m3/H 8.0m3/H Tubular Condenser
Spiral Double Tube Sheet Heat Exchanger 4.0m3/H 8.0m3/H Tubular Condenser

Henan Mikim Machinery Co., Ltd. 

Active Member
4 Years
henan, anyang
Since 2012
Business Type :
Manufacturer, Trading Company
Total Annual :
100000-200000
Employee Number :
100~150
Certification Level :
Active Member
Contact Supplier
Submit Requirement