CAFS5032 Maximum Pressure 0.8 MPa Customizable Accuracy ±1.5% FS %
How to Calculate Flow Rate
The flow rate can be determined from the sensor’s output voltage using the following formula:
Flow Rate=4V(VOUT−1V)×Full Range Flow Rate
Example Calculation:
For a CAFS5032AV sensor with a full range flow rate of 1000 SLPM, if the output voltage is 2.5V, the instantaneous flow rate can be calculated as:
Flow Rate=4V(2.5V−1V)×1000SLPM=375SLPM
Applications
- Industrial Processes: Accurate gas flow measurement for manufacturing and production lines.
- Medical Devices: Monitoring and controlling gas flow in medical equipment.
- Petroleum Industry: Measurement and control in gas extraction and processing.
- Instrumentation: Precision flow measurement for various scientific and engineering instruments.
- Laboratories: Gas flow management for experiments and research applications.
- Gas Utilities: Measurement and monitoring in gas distribution systems.
- Chemical Processing: Gas flow measurement in chemical reactions and processes.
- Smelting: Accurate gas flow control in metal smelting operations.
- Food Processing: Gas measurement for food production and packaging processes.
- Mechanical and Electrical Equipment: Integration into various systems for flow measurement and control.
Product Description
The CAFS5032 Series is a high-precision, MEMS-based flow measurement device designed for a wide range of applications. With its advanced technology and robust construction, the CAFS5032 sensor is ideal for measuring and controlling clean and relatively dry gases in industrial and commercial environments.
This sensor utilizes a state-of-the-art micro-electromechanical system (MEMS) technology that combines a thermal mass flow sensor with high-precision digital processing and calibration circuits. The integrated Δ-Σ A/D converter and internal calibration algorithms ensure accurate flow measurement with minimal external calibration requirements. The CAFS5032 offers reliable performance with various output options and can be used in diverse operational conditions.
Product Features
- High Accuracy: The CAFS5032 provides high precision with an accuracy of ±1.5% Full Scale (FS), ensuring reliable and accurate gas flow measurements.
- Linear Output: The sensor features a linear output response, which simplifies integration and application in various systems.
- No Temperature Compensation Required: The sensor's design eliminates the need for external temperature compensation, reducing system complexity and maintenance.
- Long-Term Stability: With minimal zero-drift, the sensor maintains high performance and stability over long periods.
- Fast Response Time: The sensor has a quick response time of 65 ms (selectable), enabling real-time flow measurements and quick adjustments.
- Wide Flow Range: Capable of measuring gas flows from 0 to 60 m/s, with high resistance to impacts and shocks up to 100g.
- Solid-State Sensing Core: The MEMS sensor core features no surface cavities or fragile films, making it resistant to blockages and pressure impacts.
- Versatile Output Options: Offers both analog outputs (1-5 VDC) and digital RS485 communication (MODBUS protocol) for flexible data integration and analysis.
- Adaptability to Humid Gas Environments: Suitable for measuring relatively humid gases, expanding its range of applications.
- Temperature and Humidity Range: Operates in a wide temperature range of -25°C to 85°C and storage conditions from -40°C to 90°C, with a humidity tolerance of 0-100% RH.
- Condensate Water Resistance: Designed to endure exposure to condensate water without performance degradation.
Functional Specifications
Functional Items | CAFS5032 Maximum Pressure 0.8 MPa High Precision MEMS Based Sensor | Unit | Remarks |
---|
Power Supply Voltage | 8~24 VDC, 50 mA | VDC | Selectable |
Accuracy | ±1.5% FS | % | |
Response Time | 65 ms (Selectable) | ms | |
Maximum Pressure | 0.8 MPa | MPa | Customizable |
Communication Mode | RS485 (MODBUS) | | |
Output Method | Analog outputs of 1-5 VDC, 4-20 mA | | Optional |
Temperature Range | Medium Temperature: -10~65°C, Ambient Temperature: -25~85°C | °C | |
Humidity | 0-100% RH (No ice, no condensation) | | |
Joggle | PT1/4 | | Customizable |
Calibration Method | Air, at 20°C, 101.325 kPa | | |
Material | Stainless Steel | | |