CMF5032 High Accuracy: ±1.5% Full Scale (F.S.) accuracy Storage Temperature: -40°C to 90°C
Use Instructions
- Read Instructions Carefully: Please read these instructions thoroughly before using the product.
- Clean Gas Environment: The product is best used in a clean gas environment and is not suitable for environments with a large amount of dust, oil pollution, or multiphase flow. For use in environments with large quantities of water vapor, please contact the manufacturer in advance.
- Suitable Applications: This product is suitable for gas measurement, monitoring, and control in automotive, industrial, commercial, and equipment industries. It should not be used in unsuitable environments.
- Follow Operating Specifications: During use, strictly follow relevant operating specifications and safety precautions.
- Manufacturer Liability: Wuxi Consensic Electronic Technology Co., Ltd., its branches, subsidiaries, and offices are not liable for any damage resulting from improper use of this product. Other matters are subject to the sales contract.
Important Notes
- Operating Environment: The product can only function properly within the environment defined in this manual.
- Installation and Leak Detection: Pay attention to the gas flow direction during installation and conduct connection and leakage detection according to relevant regulations.
- Pipe Installation and Cleaning: During use, avoid online pipe installation, cleaning, or other operations that may introduce a large number of impurities, as these can damage the product.
- Water in Medium: If water is present in the medium or the sensor is immersed in water, it may cause the sensor's sensitivity to decline or result in damage.
- Power Supply Polarity: Reversing the positive and negative electrodes of the power supply can burn out the internal circuit of the sensor, affecting its use.
Performance Specifications
Functional Items
Functional Items |
CMF5032 High Accuracy Full Scale Accuracy Storage Temperature -40C To 90C |
Unit |
Remarks |
Power Supply Voltage |
8~24 VDC, 50 mA |
VDC |
Selectable |
Accuracy |
±1.5 |
% FS |
|
Response Time |
65 |
ms |
Selectable |
Maximum Pressure |
0.8 |
MPa |
Customizable |
Communication Mode |
RS485 (Modbus) |
|
|
Output Method |
Analog outputs of 1-5 VDC |
|
|
|
4-20 mA |
|
Customizable |
Temperature |
Medium Temperature (-10~65), |
℃ |
|
|
Ambient Temperature (-25~85) |
℃ |
|
Interface |
PT1/4 |
|
Customizable |
Calibration Method |
Air, 20℃, 101.325 kPa |
|
|
Material |
Stainless Steel |
|
|
Product Description
The CMF5032 gas mass flow sensor utilizes a micro-electromechanical system (MEMS) flow sensor chip, suitable for various applications involving clean and relatively dry small-flow gas measurement and process control. The unique packaging technology allows the product to meet different flow measurement ranges, ensuring high sensitivity, high reliability, high stability, and low cost.
The CMF5032 series is based on the MEMS flow sensing unit and a high-precision digital processing and calibration circuit (MCU). The integrated Δ-Σ A/D converter and the logic circuit, along with the MCU processor with internal calibration functions, ensure real-time effective acquisition of sensing signals and accurate flow signals. This internal compensation algorithm processing eliminates the need for external calibration compensation, ensuring high accuracy flow output. The friendly digital output communication allows users to easily obtain relevant data information. The product has a very broad application range.
Product Features
- High Accuracy: ±1.5% Full Scale (F.S.) accuracy
- Linear Output: No need for temperature compensation
- Long-term Stability: Maintains minimal zero-drift
- Quick Response Time: 20 ms response time
- Wide Flow Range: 0-60 m/s, impact-resistant up to 100g
- Robust Sensing Core: Solid-state, no surface cavity or fragile film, resistant to blockage and pressure impact
- Output Options: Analog output (1-5 V) with optional RS485 digital communication output
- Adaptability: Suitable for relatively humid gas measurements
- Operating Temperature: -25°C to 85°C
- Storage Temperature: -40°C to 90°C
- Humidity: 0-100% RH
- Condensate Water Resistance: Sensor can withstand condensate water
The CMF5032 is designed for precise and reliable gas flow measurements, making it an essential tool in various industrial, medical, and environmental applications. Its advanced MEMS technology and robust design ensure high performance and durability.