This Chinese instruction manual is intended for your reference only.
Disclaimer
The information provided in this data sheet is solely for the implementation and use of the Consensic products. Technical specifications and characteristics are subject to change without prior noticeConsensic Have the right to change any product without further notice.
The "standard parameters" provided in this data table vary across applications, and the actual performance changes over time. The customer must Verify all operation parameters in its application.
Consensic Do not be responsible for any direct, indirect or joint losses caused by product defects, false execution, etc. In any case, regardless of the cause, Consensic shall be liable for any injury of any kind, including ——, any direct, indirect, special, incidental, incidental, punitive or other damage caused by, or in any way related to the use of the product, whether a breach of the Contract, tort (including negligence), strict liability or otherwise; and whether based on this agreement or otherwise, even if informed of the possibility of the damage; and whether persistent injury is caused Or property damage or otherwise; and whether lasting or not —— results, products or any services provided by Consensic.
The Customer assumes all responsibilities and obligations for properly and safely loading and unloading goods. Customers should take proper preventive measures to prevent static discharge. Also, please note that the Ben Products shall not be regulated compatible or agent registered (FCC, UL, CE, etc.).
No liability for granting patent rights or other intellectual property rights. Consensic, Do not undertake any application for assistance, customer product design, software performance, or patent or otherwise
Liability for any kind of infringement of intellectual property rights.
Introduce
CAFS 5012E Explosion-proof gas mass flowmeter is made of microelectromechanical system (MEMS) flow sensing chip, suitable for various uses of clean, relative, dry gas flow measurement and process control, the unique packaging technology makes the product to meet
characteristic
■ Intrinsically safe and explosion-proof type
■ High accuracy (1.5%F.S. Precision), with high long-term zero-drift stability
■ Linear output and no temperature compensation, fast response time (10 ms response time)
■ Flow range 0-60 m/s, 100g
■ Solid state sensing core (no surface cavity or fragile film), resistant to blockage and pressure impact, suitable for relatively humid gas measurement, the sensor can be resistant to condensate
■ Multiple types of output are available: analog output (15 V), I2C or RS485
■ Operating temperature: -15°C to 65°C, storage temperature: -25°C to 85°C, humidity: 0100% RH
Performance Parameter
Functional items |
CAFS5012E | ||
performance parameter | unit | remarks | |
Flow range | 0-50,80,100,150,200,250,300,400 | SLPM | customizable |
Power Supply Voltage | 8~24VDC ,50mA | VDC | |
Explosion-proof type | Ex ia IIC T6 Ga | ||
accuracy | ±1.5 | %F.S. | |
response time | 10,20,65,150 (factory default 65) | ms | customizable |
maximum pressure | 0.8 | MPa | customizable |
Output method | Analog output 1-5, digital RS485 or I2C (optional) | VDC | |
temperature | Medium temperature (-10~65) | ℃ | |
Ambient temperature (-25~85) | |||
joggle | G1/2 | customizable | |
Calibration method | Air, and the 20℃,101.325kPa | ||
The overall material | Aluminum alloy (customizable stainless steel) |