linear output
Flow rate = [(VOUT-1 V) / 4 V] Full range flow rate
For example: CAFS5012 has 100 slpm a full range flow.
When the output voltage is read at 2.5V, the instantaneous flow rate is:
[(2.5V-1V)/4V×100slpm] =37.5 slpm
performance parameter
- Flow Range: 0-50/100/200/300/400 slpm (customizable)
- Power Supply Voltage: 8~24VDC, 50mA (selectable)
- Accuracy: ±1.5% FS
- Response Time: 65 ms (selectable options: 10, 20, 30, 50, 80, 100, 200, etc.)
- Maximum Pressure: 0.8 MPa (customizable)
- Communication Mode: RS485, Modbus
- Measure the Scale Ratio: 50:1
- Output Method: Analog outputs of 1-5V (customizable)
- Temperature: Medium temperature (-10~65°C), ambient temperature (-25~85°C)
- Connection: NTP 1/2”
- Levels of Protection: IP40
- Calibration Method: Air, at 20°C, 101.325 kPa
- Overall Material: Stainless steel (aluminum alloy customizable)