stands out for its
The CPS123 SIP solution comprises a resistive bridge-type pressure sensor and a 24-bit ADC, providing high-resolution and accurate pressure measurements. The digital output is fully calibrated for pressure and temperature, simplifying usage and integration without the need for additional calibration by the host microcontroller.
Parameter | Symbol | Conditions | Min | Typ | Max | Units |
---|---|---|---|---|---|---|
Range | -40 | 85 | °C | |||
Resolution | 0.003 | °C | ||||
Accuracy | -40°C to 85°C | -1 | ±0.75 | +1 | °C |
Parameter | Symbol | Conditions | Min | Typ | Max | Units |
---|---|---|---|---|---|---|
Supply Voltage to GND | VSUPPLY | 2 | 3.0 | 5.5 | V | |
Operating Temperature Range | -40 | 85 | °C | |||
I²C Pull-Up Resistors | RPU | 1 | 2.2 | kΩ |
Parameter | Symbol | Conditions | Min | Typ | Max | Units |
---|---|---|---|---|---|---|
Pressure Range | 30 | 130 | kPa | |||
Pressure Range | 300 | 1300 | mbar | |||
Resolution | 0.001 | kPa | ||||
Resolution | 0.01 | mbar | ||||
Accuracy (70 to 115kPa @ 25°C) | -0.2 | ±0.2 | +0.2 | kPa | ||
Accuracy (70 to 115kPa, 0°C to 50°C) | -0.25 | ±0.25 | +0.25 | kPa | ||
Solder Drifts | -0.1 | +0.2 | kPa |