CPS135B Pressure Accuracy: ±0.3kPa (±3.0mbar) @ 25°C Temperature Accuracy: ±1.0°C
PARAMETER | SYMBOL | CONDITIONS | MIN | TYP | MAX | UNITS |
PRESSURE SENSOR | ||||||
Range |
50 (500) |
160 (1600) |
kPa (mbar) |
|||
Resolution1 |
0.01 (0.1) |
kPa (mbar) |
||||
Accuracy |
50 to 160kPa @25°C |
-0.3 (-3.0) |
±0.15 (±1.5) |
+0.3 (+3.0) |
kPa (mbar) |
|
50 to 160kPa (0°C to 50°C Verified) |
-0.5 (-5.0) |
±0.3 (±3.0) |
+0.5 (+5.0) |
kPa (mbar) |
||
Solder Drifts | -0.2 | +0.2 | kPa | |||
TEMPERATURE SENSOR | ||||||
Range | -40 | 85 | °C | |||
Resolution | 0.003 | °C | ||||
Accuracy | -40°C to 85°C | -1 | ±0.75 | +1 | °C | |
OPERATION | ||||||
Supply Voltage to GND2 | VSUPPLY | 2 | 3.0 | 5.5 | V | |
Operating Temperature Range | -40 | 85 | °C | |||
I2C Pull-Up Resistors | RPU | 1 | 2.2 | kΩ | ||
1Guaranteed by design of 24bits ADC, and calculated according to the range in application. 2 Factory calibrated for Pressure and Temperature at 3.0V±10%. Output accuracy will be affected if used outside this range. Other ranges available upon request. |