CAFS6000 Silicon Carbide Epoxy Resin, PPS, And Silicon Shall Serve As The Sealing Material
Safe use
Sensors are used in the explosive gas and harmful gas measurement, must be strictly in accordance with the product specification requirements and restrictions, strong corrosive gas and chloride
Gas may affect the correct measurement of the sensor and may cause sensor damage.
Test conditions: Vin = 12±0.1VDC, Ta=25°C. Relative humidity: 40% <relative humidity <60%. Maximum operating temperature range-15°C to + 70°C | |||||
specifications | 0.3-0.5MPa Custom Withstand Voltage Flow Meter 9-500ms | ||||
least value | normal value | crest value | unit | remarks | |
Flow range | 0 |
— | 10000 | sccm | Customizable specifications |
service voltage | 8-24V | V | customizable | ||
current | 50 | mA | |||
Maximum voltage output | 4.96 | 5 | 5.02 | V | linear |
Zero point voltage output | 0.98 | 1 | 1.02 | V | linear |
accuracy | 1.5 | 2 | %FS | ||
repetitiveness | ±0.3 | % | |||
resolution ratio | 0.1 | % | gamut | ||
withstand voltage | 0.3 | 0.5 | MPa | customizable | |
response time | 9 | 65 | 500 | ms | customizable |
zero drift | 0.2 | %Year | gamut | ||
Calibration conditions | 0℃, 1 standard atmosphere | ||||
The overall material | Silicon carbide, epoxy resin, PPS, and silicon shall serve as the sealing material |
Accessories selection