SMP2200 OEM flush film isolation pressure sensor
SMP2200 series flush diaphragm pressure sensor core uses MEMS silicon die, combined with our company's unique design and production process. Each product's production has adopted a strict aging, screening and testing processes, to ensure excellent quality and high reliability, and to provide high-quality products for the long-term use of customers. The product uses flush membrane thread installation structure, easy to clean, high reliability, suitable for food, hygiene or viscous medium pressure measurement.
Features
Range: -100kPa…0kPa~20kPa…35MPa
Wide temperature compensation 0℃~70℃
2 times overload pressure
SS 316L diaphgram
Application
Food, beverage, health industry
Process control
Viscous media pressure measurementn
Outline Structure:(Unit: mm)
Specification
Structrual Condition | |
Rear thread | M24*1 Internal thread |
Housing/Diaphragm material | SS 316L |
Pin Wire | Gold-plated karaf/100mm silicone rubber wire |
Back pressure tube | SS 316L (gauge and negative pressure only) |
Seal ring | Nitrile rubber |
Electrical Condition | |
Power supply | ≤2.0mADC |
Impedance input | 3kΩ~6kΩ |
Impedance output | 4kΩ~6kΩ |
Response | (10%~90%):<1ms |
Insulation resistance | 100MΩ,100V DC |
Overpressure | 2times FS, 5times for 0B/0A/02 |
Environmental Condition | |
Media applicability | Fluid which has no corrosion on stainless steel and nitrile rubber |
Shock | No change at 10gRMS,(20~2000)Hz |
Impact | 100g, 11ms |
Location effects | Deviate 90° from any direction, zero change≤±0.05%FS |
Basic Condition | |
Environment temperature | (25+/-1)℃ |
Humidity | (50%±10%)RH |
Atmospheric pressure | (86~106) KPa |
Power supply | (1.5+/-0.0015)mA DC |
All tests are in accordance with relevant national standards, including GB / T2423-2008, GB / T8170-2008, GJB150.17A-2009, etc., and also comply with the Company's "Pressure Sensor Enterprise Standards" provisions of the relevant content. |
Item | Min. | Typ. | Max. | Units |
Linearity
| ±0.15 | ±0.2 | %FS,BFSL | |
Repeatability | ±0.05 | ±0.075 | %FS | |
Hysteresis | ±0.05 | ±0.075 | %FS | |
Zero output | ±2.0 | mV DC | ||
FS output | 45 | 130 | mV DC | |
Compensated temp. range | 0~70 (0A/0B 0~60) | ℃ | ||
Working temp. range | -40~125 | ℃ | ||
Storage temp. range | -55~150 | ℃ | ||
Zero temp. error | ±0.75 | ±1.0 | %FS, @25℃ | |
Full temp. error | ±0.75 | ±1.0 | %FS, @ 25℃ | |
Long term stability error | ±0.1 | %FS/year | ||
Note:1. The above performance indicators are tested under the benchmark conditions. | ||||
2. The temperature range for temperature drift test is the compensation temperature range. |
CE Certificate: