Dual output for stainless steel silicon Pressure and temperature Sensor
SMP2081 OEM Temperature and pressure dual output pressure sensor
SMP2081 series OEM temperature and pressure dual output pressure sensor can measure the temperature and pressure critically at the same time, it has a very strong interchangeability, overall size is φ19mm ( universal ).This series of products can be reliably applied to hydraulic systems, industrial process control and hydrologica
applications.
Features
Range: -100kPa…0kPa~20kPa…70MPa
Temperature and pressure dual output
Imported chip, laser trim
Product size: Φ19mm×15mm
Application
Industrial Process Control
Hydraulic system
Gas, liquid and vapor pressure detection
Hydrological monitoring
Outline structure(unit: mm):
Specification
Construction Condition | |
Diaphragm material | SS 316L |
Housing material | SS 316L |
Pin Wire | Kovar/100mm silicone rubber wire |
Back pressure tube | SS 316L (gauge and negative pressure only) |
Seal ring | Nitrile rubber |
Electrical Condition | |
Power supply | 1.5mADC |
Impedance input | 2.5kΩ~5kΩ |
Impedance output | 2.5kΩ~5kΩ |
Response | (10%~90%):<1ms |
Insulation resistance | 100MΩ,100V DC |
Overpressure | 2 times FS |
Environmental Condition | |
Media applicability | Fluid which has no corrosion on stainless steel and nitrile rubber |
Shock | No change at 10gRMS,(20~2000)Hz |
Impact | 100g,11ms |
Position | Deviate 90° from any direction, zero change≤±0.05%FS |
Basic Condition | |
Environment temperature | (25+/-1)℃ |
Humidity | (50%±10%)RH |
Atmospheric pressure | (86~106) kPa |
Power supply | (1.5+/-0.0015)mA DC |
Parameter
Item | Min. | Typ. | Max. | Unit |
Linearity
| ±0.15 | ±0.25 | %FS,BFSL | |
Repeatability | ±0.05 | ±0.075 | %FS | |
Hysteresis | ±0.05 | ±0.075 | %FS | |
Zero output | ±2.0 | ±2.0 | mV DC | |
FS output | 45 | 100 | mV DC | |
Temperature output | PT100 Resistance output | |||
Compensated temp. range | 0~70 | ℃ | ||
Working temp. range | -40~125 | ℃ | ||
Storage temp. range | -55~150 | ℃ | ||
Zero temp. error | ±0.75 | ±1.0 | %FS@ 25℃ | |
Full temp. error | ±0.75 | ±1.0 | %FS@25℃ | |
Long term stability error | ±0.0 | %FS/year | ||
Note:1. The above performance indicators are tested under the benchmark conditions | ||||
2. The temperature range for temperature drift test is the compensation temperature range |