Contact resistance tester HYHL-400A
2. Equipment Description:
400A and 600A are same panel design.
3. Main Functions:
1 Rapid test
2 Result print
3 Upload data to PC
4.Technical Parameters:
1. Measuring range: 0-1999.9 μΩ Resolution:0.1 μΩ
2. Measuring current: DC 100A/200A/400A for different selection
3. Measuring precision:0.5 %RGD+0.05%FS
4. Display mode: LCD
5. Save no more than 100 groups of data
6. RS232 computer interface
7. Rated power supply:AC220V
8. Size: 340 × 280 × 210mm3
9. Environment temperature:-10 ℃~+40 ℃ Relative humidity<80%
5. Product Picture:
TAGS
DC Contact Resistance Meter / Digital Contact Resistance Tester / Micro Ohmmeter / Low Resistance ohmmeters / Low Resistance Tester / Measure Contact Resistance