ROHS 18.5 Inch Lcd Capacitive Touchscreen 10 Points USB Interface
Basic specification of Touch Screen:
Size | 18.5inch |
Total thickness | 2.4±0.3mm |
Outline of Cover Lens | 446.05*271.18±0.3mm |
Outline of ITO Sensor | 427.1*249.68±0.3mm |
Viewing Area | 410.8*231.4±0.3 mm |
Active Area | 413.8*234.4±0.3 mm |
Interface | USB |
Input voltage | 5V |
Response time | 10ms |
Panel color | Black |
Transmittance | ≧85% |
Input method | Hand writing or capacitive pen |
Capacitance touch screen technology description:
Capacitive touch screen is a four-storey glass screen surface and laminated within the glass screen is coated with a layer of ITO, the outermost layer is a thin layer of silica glass, laminated ITO coating as a face, four electrode leads in the four corners, inner ITO good shielding to ensure a good working environment.
When finger touch the metal layer that is, because the body farm, users and touch-screen surface with a coupling capacitor, high frequency current, capacitance is a direct conductor, so fingers sucked away a very small amount of current from the contact point. The respectively current outflow from the touch electrode on the four corners of the screen, and flows through the four electrode current is proportional to the distance from the fingers to the four corners, controller through the accurate calculation of the four current percentage, came to the location of the touch point.
Features of PCAP:
1. Projected Capacitive touch screen
2. Customization
3. 3.5 inch to 70 inch(More large sizes products are developed now)
4. Multi touch point
5. OS support:Windows 7/8/10,Android,Linux,XP,WCE
6. USB interface
7. Low MOQ
Reliable Testing of Touch Screen:
Working temperature and humidity | -20~+70℃, 20~85%RH |
Storage temperature and humidity | -30~+80℃, 20~85% RH |
Humidity resistance | 85% RH, 120H |
Heat resistance | 70℃, 120H |
Cold resistance | -20℃, 120H |
Thermal shock | -20 ℃ (0 . 5hour)-70 ℃ (0 . 5hour) by 50 cycles |
Humidity resistance | The requirement shall be satisfied after being exposed at 85% RH for 120 hours and normal temperature and humidity for 24 hours. |
Heat resistance | The requirement shall be satisfied after being exposed at 80℃ for 120 hours and at normal temperature and humidity for 24 hours. |
Cold resistance | The requirement shall be satisfied after being exposed a t -30℃ for 120 hours and at normal temperature and humidity for 24 hours. |
Thermal shock | The requirement shall be satisfied after being exposed at -30℃ (0.5 hour)—80℃(0.5hour)by 50 cycles and at normal temperature for 24 hours |