JIAPENG WWY-30~/40-150 TYPE oIL FREE Oxygen Booster Supercharger Air compressor O2 High booster for Oxygen filling
About shanghai powerbuilder automation technology co.,ltd
- We are the authorized distributor of Anshan Jiapeng. We have been engaged in the assembly of PSA nitrogen generators and oxygen generators in our factory for 15 years, providing approximately 400 sets of PSA nitrogen generators and oxygen generators for domestic and international customers each year, including production, and debugging.
- In collaboration with Burkert Valves, we have customized our own double-acting pneumatic valve. Through the design of top and middle pressure equalization,and airflow orifice plates, we continuously optimize and reduce the air consumption ratio of the equipment, thus achieving energy savings. The energy consumption ratio of our equipment has reached the highest level in China. And through our patented silencer, our device noise is controlled to less than 55 db.
- In terms of process flow, we have cutting, welding, assembly, filling of molecular sieves, automatic rust removal, spraying, and complete procedures and supporting equipment for commissioning.
- In the supply chain aspect, we provide first-line brands such as Atlas Copco, Ingersoll Rand, GDK, Liutech, Bolaite, Hanbell, and BK for air compressors, and provide Boly, Atlas Copco, and Liutech refrigerated dryers, as well as Anshan Jiapeng and Anqing Bailian boosters.
- We can provide supporting equipment and accessories.
- Currently, our company's products are aimed at end-users and distributors worldwide. We provide customized remote systems, color customization, display interface customization, and many other OEM services. And we also provide ASME standard equipment and pressure tanks for USA and Australian market.
- For specific selection, please contact our customer manager. We hope to become your trusted long-term partner.
About Anshan Jiapeng Compressor Co., Ltd
Anshan Jiapeng Compressor Co., Ltd. is located in the southeast of Liaoning Province, located in the steel capital - Anshan, the company was established in June 1998, the registered capital of 5 million yuan, after the reform of the state-owned enterprises, the first production of oil-free gas compressor joint-stock companies, is the earliest domestic production license manufacturers. The company mainly produces 10 series of compressors with more than 100 models of oil-free air, oxygen, nitrogen, argon, helium, carbon dioxide, sulfur hexafluoride and other non-flammable and explosive gases. At the same time, supporting post-treatment equipment, cold and dry machines, filters, gas storage tanks, to provide users with oil-free, water-free, dust-free and sterile purified air. Fat-filling oil-free compressor can change the original old model structure, convenient maintenance, prolong the service life, has won the national patent (patent no. ZL 20112 0053943.2) is the first compressor production license and general machinery GC certification unit, and through the ISO9001-2008 system certification. National quality qualified products. National mechanical and electrical products energy efficiency grade certification, for many years by anshan Industrial and commercial bureau as industry and commerce exempt enterprises, abide by the contract heavy credit enterprise, Anshan technical supervision bureau "anti-counterfeiting and fidelity enterprise".

Working Principle
- Compression of gas: The air compressor draws in a large volume of air through one or more cylinders and compresses it using a piston or a screw-type compression device. As the gas is compressed, the molecular spacing decreases, resulting in increased gas pressure and temperature.
- High-Pressure Gas Discharge: Following the compression process, the compressed gas is discharged into either a storage tank or a network of delivery pipelines. These mechanisms facilitate the efficient distribution and utilization of the high-pressure gas.
- In the case of a storage tank, it serves as a reservoir for the compressed air, ensuring a steady and balanced supply. The tank acts as a buffer, accumulating the compressed air during low-demand periods and releasing it when there is a need for a higher volume of air. This helps maintain a consistent and reliable supply of compressed air, accommodating fluctuations in demand and optimizing overall system performance.
- Alternatively, the compressed gas can be directed into delivery pipelines, which transport the high-pressure air to specific points of use. These pipelines are designed to efficiently distribute the compressed air, ensuring it reaches the desired locations safely and effectively. By utilizing a network of delivery pipelines, the compressed gas can be readily accessed at various points throughout the facility, enabling its use for operating pneumatic tools, machinery, or other applications.
- The choice between a storage tank and delivery pipelines depends on factors such as the scale of the operation, required air capacity, and system design considerations. Both options facilitate the effective discharge and utilization of high-pressure gas, ensuring a reliable supply of compressed air for a wide range of industrial and commercial purposes.
- Overall, the discharge of high-pressure gas into storage tanks or delivery pipelines plays a crucial role in maintaining a consistent and balanced supply of compressed air, enabling efficient and reliable operation of pneumatic systems and equipment.
- Control system: Air compressors are typically equipped with a control system to monitor and regulate the gas pressure. When the pressure drops below a set value, the control system starts the compressor to increase the gas supply. When the pressure reaches the preset upper limit, the control system stops or reduces the operation of the compressor.
- Cooling system: During the compression process, the temperature of the gas increases. Therefore, air compressors are usually equipped with a cooling system to lower the gas temperature. This can be achieved through air cooling or water cooling.
- Lubrication System: In order to minimize friction and wear, air compressors incorporate a vital lubrication system that ensures the proper functioning of the compression device and other moving components.
- The lubrication system is responsible for delivering lubricating oil or lubricants to critical areas within the compressor. This lubricating substance forms a protective film between the moving parts, reducing friction and heat generation during operation. By providing a smooth interface between the components, the lubrication system helps to enhance efficiency, extend the lifespan of the compressor, and maintain optimal performance.
- The lubrication system typically consists of an oil reservoir or sump, a pump, and a network of passages or channels that distribute the lubricant to the necessary areas. The pump draws oil from the reservoir and delivers it under pressure to the compression device, such as pistons or screws, as well as bearings, crankshafts, and other moving parts that require lubrication.
- Regular maintenance of the lubrication system is crucial to ensure the proper functioning of the compressor. This includes monitoring oil levels, checking for contamination, and performing scheduled oil changes or filter replacements as recommended by the manufacturer. By maintaining a well-functioning lubrication system, the compressor can operate smoothly, reducing friction-related issues, minimizing wear, and maximizing its operational lifespan.
In summary, an air compressor compresses a large volume of air into high-pressure gas to meet the compressed air requirements in various industrial and commercial applications. The key steps in the working principle include gas compression, discharge of high-pressure gas, control system, cooling system, and lubrication system.
Product description
Lot. | Item | Parameter |
1 | The compression medium | Oxygen (must be dry and free of particulate gas) |
2 | Model | WWY-30/4--150 |
3 | Flow rate (standard) Nm3/h | 30 |
4 | Inlet temperature ℃ | ≤40 |
5 | Inlet pressure MPa | 0.4 |
6 | Outlet Pressure MPa | 15 |
7 | Cylinder diameter quantity | Φ90+φ50+φ30 mm |
8 | Revolving Speed r/min | 470 |
9 | Cooling Mode | Air cooling + water cooling (in circulation) |
10 | Lubrication method | Oil free lubrication |
11 | Compressed series | Three Level |
12 | Structural style | Angle type, W type, single unit |
13 | Motor | Power kW | 15 |
The electric system | AC380V, three-phase electricity, 50Hz, |
Insulation grade | B Grade |
Protection grade | IP44 |
Start Mode | Direct Starting |
14 | Drive Mode | Belt Drive |
15 | The installation type | The base type |
16 | Noise Figure dB(A) | ≤80 |
17 | Control mode | PLC Touch screen control: maintenance alarm, over temperature alarm, overpressure alarm, motor overload alarm and so on |
18 | Dimension of inlet and outlet | Rc1/2 Rc5/8 |
19 | Size(L×W×H) mm | 1350*1000*1100 |
20 | Weight kg | ≈450 |
Lot. | Item | Parameter |
1 | The compression medium | Oxygen (must be dry and free of particulate gas) |
2 | Model | WWY-40/4--150 |
3 | Flow rate (standard) Nm3/h | 40 |
4 | Inlet temperature ℃ | ≤40 |
5 | Inlet pressure MPa | 0.4 |
6 | Outlet Pressure MPa | 15 |
7 | Cylinder diameter quantity | Φ90+φ50+φ30 mm |
8 | Revolving Speed r/min | 580 |
9 | Cooling Mode | Air cooling + water cooling (in circulation) |
10 | Lubrication method | Oil free lubrication |
11 | Compressed series | Three Level |
12 | Structural style | Angle type, W type, single unit |
13 | Motor | Power kW | 15 |
The electric system | AC380V, three-phase electricity, 50Hz, |
Insulation grade | B Grade |
Protection grade | IP44 |
Start Mode | Direct Starting |
14 | Drive Mode | Belt Drive |
15 | The installation type | The base type |
16 | Noise Figure dB(A) | ≤80 |
17 | Control mode | PLC Touch screen control: maintenance alarm, over temperature alarm, overpressure alarm, motor overload alarm and so on |
18 | Dimension of inlet and outlet | Rc1/2 Rc5/8 |
19 | Size(L×W×H) mm | 1350*1050*1100 |
20 | Weight kg | ≈450 |
The basic parameters listed in this table can be confirmed according to the actual working conditions
- Touch display PLC control
- Remote control is optional
- Inlet and outlet pressure overload, temperature overheating, cooling water failure,circulation rolling alarm and stop
- Operation time display, maintenance cycle prompt
- With water tank and circulating pump without external pipeline, filling antifreeze at low temperature without obstruction.